Before you begin

Model 1532 only - Preparing third party solar showers for use with system.
Water containers that have shutoff valves at the outlet port are not
advised for use with the ShowerCoil system. However, if they are used,
extra care must be taken to ensure each valve is fully open during the
heating process to maintain unrestricted water flow. Failure to do so can
damage or melt the heating coil due to absent or inadequate water flow
and produce steam or overheated water causing a risk of injury including
burns.
1.
Remove existing shower hoses from outlet port of third party solar showers if present.
2.
Slide supplied adapter connectors onto outlet ports.
a.
Outlet port outer diameter of solar shower must be between 0.43-0.50 inches (11-12.7mm).
3.
Before filling cold water supply bag, temporarily insert supplied shower head into adapter connector
to plug outlet.
4.
Close pinch valve
© 2015 BoundaryTEC, LLC.
DOC: 100-032E
7
Questions?
800.753.9943
support@boundarytec.com
www.boundarytec.com
Operation – Water Heating
5.
Fill Supply Water Bag.
a.
Fill one bag with clean water.
Note: If collecting water from a lake or river, hold the bag as shown below
and horizontally scoop undisturbed water a few inches below the
surface. This technique allows the cleanest water to be collected.
b. Fold the top flap toward the front translucent side of the bag and
press out some of the trapped air.
c.
Roll over the top edge of the bag 4x towards the front
translucent side of the bag while ensuring that the front ply of
the bag stays in contact with the back ply and does not slide
apart or wrinkle.
d. Bend the ends of the buckles back around toward the fabric
side of the bag and snap.
6.
Elevate Supply Bag
a.
Suspend the filled supply bag as
shown so its drain port is 30-36
inches above the empty bag on the
ground.
b. Suggested options for suspending
i. Suspend from tree limb if
available.
ii. Field constructed tripod
Lash 3 sticks together with a
cord as shown. Sticks should
be about 5 feet in length.
iii. BoundaryTEC Aluminum Tripod
Stands
PN: 1540 or 1542.
7.
Uncoil heating assembly and
straighten out rubber tubing,
ensuring there are no kinks.
8.
Flatten and force any air out of the empty bag before closing up. Evacuating the air will ensure there
is enough room for the all of the flowing water during the heating process.
a.
Ensure the lower empty bag is equal to or larger in size than the supply bag if using 3
shower bags.
© 2015 BoundaryTEC, LLC.
Accessory
rd
party
DOC: 100-032E
8
Questions?
800.753.9943
support@boundarytec.com
www.boundarytec.com
bag: