Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Chicago, IL 60631
Phone: 1-800-628-9439
Web Site: masterplumberpump.com
installation, or maintenance assistance:
© 2011
Models 633752, 633766
Installation/Operation/Parts
For further operating,
Call 1-800-628-9439
O W N E R ' S MA N UA L
Submersible Sump Pumps
TRU699 (Rev. 5/12/2011)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 633752 and is the answer not in the manual?

Questions and answers

jesse climaco
April 19, 2025

what kind and what of capacitor in for 633752 - 01 submersible sump pump

1 comments:
Mr. Anderson
May 10, 2025

The Master Plumber 633752 submersible sump pump uses a permanent split capacitor motor.

This answer is automatically generated

jesse climaco
April 19, 2025

what size of capacitor i need

Summary of Contents for Master Plumber 633752

  • Page 1 O W N E R ’ S MA N UA L Submersible Sump Pumps Chicago, IL 60631 Phone: 1-800-628-9439 Web Site: masterplumberpump.com Models 633752, 633766 Installation/Operation/Parts For further operating, installation, or maintenance assistance: Call 1-800-628-9439 © 2011 TRU699 (Rev. 5/12/2011)
  • Page 2: Specifications And Safety

    Be sure to install the check valve your local fire department for instructions. After so that the flow will be away from the pump. turning off the power, remove the pump for service. For parts or assistance, call Master Plumber Customer Service at 1-800-628-9439...
  • Page 3: Installation

    For parts or assistance, call Master Plumber Customer Service at 1-800-628-9439...
  • Page 4 Do not cut off the round ground pin. For parts or assistance, call Master Plumber Customer Service at 1-800-628-9439...
  • Page 5: Operation

    LIFT: Lift is the vertical distance the pump actually lifts water. The higher the lift, the lower the flow. For parts or assistance, call Master Plumber Customer Service at 1-800-628-9439...
  • Page 6: Repair Parts

    Impeller† PS5-34P PS5-22P • Vertical Float Switch Assembly FPS17-70 FPS17-70 • Not illustrated. NOTICE : If motor fails, replace entire pump. † See Page 8 for impeller replacement instructions. For parts or assistance, call Master Plumber Customer Service at 1-800-628-9439...
  • Page 7: Troubleshooting Chart

    Remove the pump and clean out the intake screen. Check valve is installed either Be sure the check valve is installed correctly (the flow arrow should point away from the pump). backward or upside down. For parts or assistance, call Master Plumber Customer Service at 1-800-628-9439...
  • Page 8: Impeller Replacement

    NOTICE : The impeller has a left-hand thread, so it and you should not hear any sounds of scraping or loosens to the right ( dragging from the pump. For parts or assistance, call Master Plumber Customer Service at 1-800-628-9439...
  • Page 9: Limited Warranty

    If, within twenty-four (24) months from the original consumer purchase, any such product shall prove to be defective, it shall be repaired or replaced at MASTER PLUMBER’s option, subject to the terms and conditions set forth below. The original purchase receipt and product warranty information label are required to determine warranty eligibility.
  • Page 11 U S UA R IO Bombas sumergibles para sumideros Chicago, IL 60631 Teléfono: 1-800-628-9439 Dirección web: masterplumberpump.com Modelos 633752, 633766 Instalación/Operación/Piezas Para mayor información sobre el funcionamiento, instalación o mantenimiento de la bomba: Llame al 1-800-628-9439 © 2011 TRU699 (5/12/2011)
  • Page 12: Especificaciones

    Después de desconectar la corriente eléctrica, saque la bomba para realizar los trabajos de reparación o mantenimiento. Para refacciones o asistencia, llame a Master Plumber Servicios al Cliente al: 1 800 365-6832...
  • Page 13: Instalación

    Verifique que el orificio se bomba se encienda o se apague. encuentre debajo de la línea de agua y por debajo de la válvula de retención. Para refacciones o asistencia, llame a Master Plumber Servicios al Cliente al: 1 800 365-6832...
  • Page 14 No corte la punta redonda de conexión a tierra. Para refacciones o asistencia, llame a Master Plumber Servicios al Cliente al: 1 800 365-6832...
  • Page 15: Operación

    LEVANTE (ALTURA): El levante (la altura) es la distancia tubería. vertical efectiva a la cual la bomba levanta el agua. Cuanto más alto sea el levante, menor será el flujo. Para refacciones o asistencia, llame a Master Plumber Servicios al Cliente al: 1 800 365-6832...
  • Page 16 • No se ilustra. AVISO : Si falla el motor, reemplace toda la bomba. † Consulte la página 18 para obtener las instrucciones sobre cómo reemplazar el impulsor. Para refacciones o asistencia, llame a Master Plumber Servicios al Cliente al: 1 800 365-6832...
  • Page 17: Localización De Fallas

    Verifique que la válvula de retención se haya instalado correctamente (la flecha del flujo debe apuntar en dirección contraria a la bomba). revés o boca abajo. Para refacciones o asistencia, llame a Master Plumber Servicios al Cliente al: 1 800 365-6832...
  • Page 18 AVISO : El impulsor tiene una rosca izquierda, de manera que se afloja hacia la derecha ( Para refacciones o asistencia, llame a Master Plumber Servicios al Cliente al: 1 800 365-6832...
  • Page 19: Garantía Limitada

    NO devuelva una bomba cloacal (que se haya instalado) a su tienda minorista. Comuníquese con el Departamento de Atención al Cliente de MASTER PLUMBER. Las bombas cloacales que hayan estado en servicio y se hayan removido pueden representar un peligro de contaminación.

This manual is also suitable for:

633766

Table of Contents