Download Print this page

unareti SMART METER 2.0 Instruction Manual

Cemi-direct three-phase meter
Hide thumbs Also See for SMART METER 2.0:

Advertisement

Quick Links

SMART METER 2.0
The latest-generation
electronic meter for
efficiently managing
your energy
consumption
semi-direct
three-phase meter
INSTRUCTION
MANUAL

Advertisement

loading

Summary of Contents for unareti SMART METER 2.0

  • Page 1 SMART METER 2.0 The latest-generation electronic meter for efficiently managing your energy consumption semi-direct three-phase meter INSTRUCTION MANUAL...
  • Page 3 The new electronic meter makes it possible to check consumption at any time and to know how much power electronic equipment is absorbing. How Does my new meter work? DISPLAY Information about the electricity supply can be seen on the display at the centre of the meter.
  • Page 4 and is shown on the display both as a message in the sequence and in the explanation of symbols. CONSUMPTION INDICATORS These are the 2 LEDs on the left of the display, which flash when electricity is being consumed. The frequency of the flashing increases as consumption rises.
  • Page 5: Instantaneous Power

    wHat appears on tHe DispLay? By pressing the button in sequence, the following information is displayed. IT0123E00021122 POD NUMBER is the alphanumerical code that identifies the supply. Fascia in uso F3 TIME BAND IN USE indicates the time band that is applied at the time of reading the display (F1, F2, F3).
  • Page 6 LETTURA-POTENZA READING THE CONSUMPTION AND THE POWER To obtain the actual values the displayed data must be multiplied by the KT transformation constant. POWER-READING indicates the start of a sequence of information on consumption and the absorbed power. CURRENT PERIOD corresponds to the data recorded up to the time the display is read.
  • Page 7 Data 01/01/2020 Ora 16:03:04 DATE AND TIME the date and time when the meter is read. 800 933 301 NUMBER FOR REPORTING FAULTS Unareti’s Emergency Number for reporting faults or anomalies of the electricity network and hazardous situations regarding electrical installations.
  • Page 8 manaGement of avaiLaBLe power The GESIS meter, like the previous model, has no isolator/switch to cut off the electricity supply if the available power is exceeded. In GESIS meters, the power output is controlled by measuring the maximum average power over 15 minutes recorded over a month (Max.
  • Page 9 In cases in which the Max. Pow. exceeds, for at least two months of the year, the available power, Unareti will proceed to charge the fees for the adjustment of the available power, as set out by the Regulatory Authority for Energy, Networks and the Environment (Autorità...
  • Page 10 For more information unareti.it To report faults or anomalies in the electricity network and hazardous situations regarding electrical installations 800 933 301...
  • Page 11 Certifications The CE marking and the supplementary metrology marking (indicated by the letter capital M and the last two numbers of the year the marking was affixed, inscribed in a rectangle) confirm the meter’s compliance with the European Community Directive 2014/32/EU (MID directive). Certification of the meters, in compliance with the MID directive, was carried out by a notified body, accredited at the European level in compliance...
  • Page 12: Declaration Of Conformity

    Pagine/ Contatore-La-Qualita.aspx The radio module is for the exclusive use of Unareti S.p.A., which uses it in addition to or as a replacement for the main transmission module. The meter’s certified software version can be found directly within the information on the meter’s display.