Changing A Had Socket Bit - Saltus GFA-COT Product Instructions

Closed-end and offset geared front attachments
Table of Contents

Advertisement

Operation
WARNING Crushing Hazard
The Dual trigger forces the user to use both hands to operate the tool. If not used, the operator can
accidentally start the tool while adjusting the crowfoot, thus resulting in a serious hand injury.
Make sure the tool cannot be started once the Dual trigger has been released.
Always test the tool by first releasing the trigger of the Dual trigger, then push the trigger of the
tool. If the tool starts; stop working.
WARNING Risk of Injury
Make sure that the correct parameter file is being used. Wrong Parameter File might cause too high
torque with bodily injury as a result.
Compare the maximum torque which is shown in the controller, with the maximum torque stated
in the stated technical data for the tool, they should be the same.
NOTICE Insufficient Lubrication
If the system is not sufficiently lubricated, it may be damaged.
Lubricate the system as soon as there is no longer visible grease.
Apply the grease gun to every grease nipple. Fill with lubricant until it emerges on the output socket.
Tightening procedure:
1.
Place the GFA system (1) with the socket (2) onto the screw connection (3).
2.
Check that the system is placed correctly on the head of the nut.
3.
Start tightening by using the drive unit.
4.
Remove the system from the screw connection. The system can now be positioned on the next con-
nection.

Changing a HAD Socket Bit

To Remove a Bit:
1.
Loosen and remove the set screw from the socket.
2.
Remove the bit.
8
EN
© Saltus Industrial Technique AB - 9839 1815 01
GFA-COT

Advertisement