1.
DustBlockers can only be used for filtering dry, non-explosive dust.
2.
DustBlockers cannot be used in moist rooms or rooms where an explosion hazard
may exist.
3.
MaxVac cannot be held liable if the DustBlocker is used for other applications or if the
DustBlocker is not used in accordance with this manual.
GENERAL
When removing the packaging, please check whether the DustBlocker has been
damaged during transport.
Damaged cables that have been bent or torn can be dangerous during use of the device
and must be replaced immiediately in order to prevent personal injuries.
In order to prevent personal injuries and property damages you must place the device on
a sturdy base so the DustBlocker cannot fall over.
Make sure you keep fingers clear when opening and closing the machine filter housing.
In order to prevent a risk of explosion, you should not place the device in a room that
may contain explosive gasses.
Switch the unit to the off position (0) before removing the plug from the socket. If the
switch is on sparks may be generated between the socket and the plug of the device.
Prior to performing maintenance, first remove the plug from the socket in order to prevent
electrical shock.
When replacing the pre filter or hepafilter it is possible that dust is dispersed that can be
dangerous for people's health. Therefore, users should wear safety glasses, safety gloves
and a respiration mask that comply with protection class FFP3.
Do not drill through or break open the H14 hepafilter.
DB500 DUSTBLOCKER

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DB500 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for MaxVac DB500

  • Page 1 DustBlockers cannot be used in moist rooms or rooms where an explosion hazard may exist. MaxVac cannot be held liable if the DustBlocker is used for other applications or if the DustBlocker is not used in accordance with this manual.
  • Page 2 OPERATION The operating panel is at the side of the DustBlocker and is identical for all models. At the top of the operating panel you will see from left to right: Red led with a warning signal (gives a signal if the H14/G4 filter has to be replaced) (1) Red switch (position 1-0) (2) Connect the plug to the socket on the front of the machine to start the...
  • Page 3 FILTER INDICATOR The DB500 is provided with a filter indicator connected to a warning led that measures the pressure drop in the filter. In case of a pressure drop that is too high, the red led will light up and the hepafilter must be replaced. If the DustBlocker is used while the warning led lights up, this could affect the operation of the device.
  • Page 4 WARRANTY MaxVac devices and accessories are supplied with a 24 month warranty on material and manufacturing defects. Keep (the copy of) your receipt in order to be able to submit the correct purchase date, if necessary. Never try to repair the DustBlocker yourself without prior approval from the manufacturer.

Table of Contents