SHEKEL Healthweigh H741-00 Operation Manual

Digital veterinary scales

Advertisement

Healthweigh™
DIGITAL VETERINARY SCALES
MODEL H741-00; H740-00
OPERATION MANUAL
Cat No. AA0370-3
06 July 2008

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Healthweigh H741-00 and is the answer not in the manual?

Questions and answers

Summary of Contents for SHEKEL Healthweigh H741-00

  • Page 1 Healthweigh™ DIGITAL VETERINARY SCALES MODEL H741-00; H740-00 OPERATION MANUAL Cat No. AA0370-3 06 July 2008...
  • Page 2: Table Of Contents

    HEALTHWEIGH™ DIGITAL SCALES DIGITAL VETERINARY SCALE Congratulations purchasing Healthweigh™ Digital Veterinary Scale, Model H740-10. This versatile scale is designed for weighing medium sized to small animals. The scales are equipped with movement compensation weighing technology to eliminate involuntary movement of the animal. Before attempting to operate the scale, please read this manual carefully and keep it handy for future reference.
  • Page 3: Caution And Warning

    CAUTION AND WARNING • To prevent injury, never leave an animal unattended while on the scale. • To prevent injury, do not transport the scale while the animal is in the weighing tray. • For accurate animal weighing, the scale must be placed on a flat, stable surface. •...
  • Page 4: Certification

    CERTIFICATION Healthweigh™ products are the result of 30 years technology experience and are quality confirmed by authorities, institutes and the legal system as follows: In 1995 the manufacturer was audited and certified for ISO 9001:2000. ISO 9001 Certification recognizes the manufacturer's ISO 9001:2000 quality system conforms to international standards for quality management and assurance.
  • Page 5 SPECIFICATIONS GENERAL Digital Veterinary Scale, model H740-10, uses sophisticated microprocessor Healthweigh™ Indicator technology. Each precision instrument designed provide accurate, reliable repeatable weight measurements with features that make the weighing process simple, fast and convenient. The scale is set up to use motion-sensing weighing technology to determine the actual weight of an active animal.
  • Page 6: Set Up

    SET UP This H710-10 digital veterinary scale has been calibrated at the factory. It is shipped in four parts: the base assembly, display assembly, rubber mat and rubber feet. Take the H740-10 Veterinary scale out of the packaging. Remove each piece from its packing material and unwrap carefully...
  • Page 7 Place the rubber mat on the base assembly, inside designated frame. . To operate using the AC adaptor, insert the AC adaptor cable into the back of the indicator and the AC adaptor plug in to a power source. rechargeable batteries automatically go into recharge mode when the AC adaptor is connected to...
  • Page 8: Operating Instructions

    OPERATION INSTRUCTIONS Item Item Operation Function For On – one short push On-Off Turns scale ON and OFF For Off – one long push When scales are turned on, Zero Zeros the scale prior to weighing one short push Hold the key down for 3 Prompts entry of TARE value Tare long seconds...
  • Page 9 Using the Tare Function The Tare function is used to deduct accompanying weight (such as collar or bandaging attached to the animal). Tare function can be set either manually or automatically: Manual mode: The scale display must show 0.0lb/kg on the right hand side of the display and ZERO in the upper left hand corner.
  • Page 10: Maintenance

    MAINTENANCE GENERAL This section provides instructions for maintenance, cleaning, troubleshooting and operator replaceable parts for the Digital Veterinary Scale Model H740-10. Maintenance operations other than those described in this section should be performed by qualified service personnel. MAINTENANCE Before first use and after periods of non-use, check the scale for proper operation and function.
  • Page 11: Troubleshooting

    TROUBLESHOOTING Refer to the following instructions to check and correct any failure before contacting service personnel. POSSIBLE SYMPTOM CORRECTIVE ACTION CAUSE Scale does not turn on Dead battery Connect scale to power source Faulty electrical Use a different outlet outlet Bad power Replace adaptor supply...
  • Page 12 ERROR LIST ERROR NO. DEFINITION CHECK/REPLACE Err 2 Low saturation state (Low A/D) The load cell is not connected properly. Check the cables, and mechanical connection. If the problem persists, replace the set of load cells Err 3 High saturation state (High A/D) See Err 2 Err 6 Unstable weight.
  • Page 13: Calibration Procedure

    CALIBRATION PROCEDURE mportant: Scales with OIML Class III compliance have a seal to prevent any unauthorized person performing calibration. The calibration sequence is conducted as follows: The calibration procedure is performed using a known dead weight in either kg's or lbs To turn on the scales >...
  • Page 14: Exploded View Of Scale

    EXPLODED VIEW OF SCALE H740-10 DWG NO. TITLE: DIGITAL VETERINARY SCALE BC3312 MODEL NO: H741-00; H740-00 P 14...
  • Page 15: Parts List

    PARTS LIST H740-10 ITEM DESCRIPTION QNT. CAT No. RUBBER PLANE 464114 NEW COVER PLANE 504529 SCALE BASE ASSEMBLY 504519 LOAD CELL 1028 75Kg 234168 PAN CROSS HEAD SCREW NC6X1/4 401496 JUNCTION BOX 213832 STRAIN RELIEF BUSHING SR-5L-1 407621 MODEL LABEL 270kg USA RICE LAKE 251923 RUBBER LEG NC3/8"...
  • Page 16: Warranty

    The original purchaser of the product must have proof of purchase to receive warranty service. Shekel dealers or retail stores selling Shekel products do not have the right to modify or in any way change the terms and conditions of this warranty.
  • Page 17 HEALTHWEIGH™ Shekel Electronic Scales Kibbutz Beit Keshet, MP Lower Galilee, Israel 15247 P 17 Tel: +972 4 662 9100 www.shekelonline.com...

This manual is also suitable for:

Healthweigh h740-00