DISCHARGE POWER SUPPLY MANUAL MODEL DC3005, MODEL 30010, MODEL 15012 CONTENTS Contents 1 GENERAL INFORMATION ................1-1 1.1 Introduction ..................... 1-1 1.2 Safety ..................... 1-1 1.3 Specifi cations ..................1-2 1.3.1 Dimensions ..................1-2 1.3.2 Weight .................... 1-2 1.3.3 AC Input ..................1-2 1.3.4 DC Output ..................
Page 3
DISCHARGE POWER SUPPLY MANUAL MODEL DC3005, MODEL 30010, MODEL 15012 CONTENTS Tables Table 1-1 Maximum Power, Voltage, and Output ..........1-3 Table 2-1 Inventory List..................2-1 Table 3-4 Analog connections................3-7 Table 3-4 Interlock connections................ 3-9 Table 4-1 Help codes and error messages for the Discharge Power Supply. .. 4-1 Figures Fig.
DISCHARGE POWER SUPPLY MANUAL MODEL DC3005, MODEL 30010, MODEL 15012 GENERAL INFORMATION 1 GENERAL INFORMATION 1.1 Introduction The Kaufman & Robinson, Inc. Discharge Power Supply is designed for use with a Kaufman & Robinson Ion Source. The intended use of this Power Supply is to provide DC voltage and current to the Ion Source Anode for ion production.
Continuous duty operation is specifi ed at 2000 watts up to 40˚C ambient air temperature. The maximum output for the DC3005 model of this Power Supply is 300 VDC and 5 amps. Operation at this level is limited by thermal protection.
DISCHARGE POWER SUPPLY MANUAL MODEL DC3005, MODEL 30010, MODEL 15012 GENERAL INFORMATION Table 1-1 Maximum Power, Voltage, and Output Maximum Maximum Maximum Model Power Voltage Current 3005 1500 W 300 V 30010 2000 W 300 V 10 A 15015 2000 W...
DISCHARGE POWER SUPPLY MANUAL MODEL DC3005, MODEL 30010, MODEL 15012 INSPECTION AND INSTALLATION 2 INSPECTION AND INSTALLATION This section describes how to install the Kaufman & Robinson, Inc., KRI® Dis- charge Power Supply which has been designed for operation of a KRI Ion Source.
DISCHARGE POWER SUPPLY MANUAL MODEL DC3005, MODEL 30010, MODEL 15012 INSPECTION AND INSTALLATION selects between the output VOLTAGE, or CURRENT adjustment for the far right ecoder knob. The left display shows the Discharge voltage setpoint or readback in volts. The right display shows the Discharge current setpoint or readback in amps.
DISCHARGE POWER SUPPLY MANUAL MODEL DC3005, MODEL 30010, MODEL 15012 INSPECTION AND INSTALLATION 2.4.3 Electrical-connections to ion source and discharge power supply Located on the back panel of the Power Supply are two sections of three con- nectors each for connecting the Discharge Power Supply directly to the ion source or through a KRI Filament Power Supply.
DISCHARGE POWER SUPPLY MANUAL MODEL DC3005, MODEL 30010, MODEL 15012 OPERATION 3 OPERATION The Discharge Power Supply can be operated in Local and Remote modes. Mode selection between Local and Remote modes is controlled using a Momentary Push Button located on the front panel of the Power Supply.
DISCHARGE POWER SUPPLY MANUAL MODEL DC3005, MODEL 30010, MODEL 15012 OPERATION given time. The load will determine the other. Example: If the Discharge set- points are 5 amps and 200 volts and the load is 25 Ohms then the output will be limited to 5 amps and the output voltage will be 5x25 = 125 volts according to Ohms law (V = IxR).
DISCHARGE POWER SUPPLY MANUAL MODEL DC3005, MODEL 30010, MODEL 15012 OPERATION control the Discharge Power Supply only. 3.2.1 Direct RS-232 connection from computer to discharge power supply The Discharge Power Supply can be operated from a host computer using an RS-232 port on the computer. Connection from the computer is made from a serial port on the computer to the serial port on the Discharge Power Supply, labeled, “RS-232”.
Page 15
DISCHARGE POWER SUPPLY MANUAL MODEL DC3005, MODEL 30010, MODEL 15012 OPERATION zero output, it also puts the unit in standby mode, while VA4095 is .. maximum output. • VBxxxx Sends a Voltage setpoint to the Discharge Power Supply. . Note: xxxx is a decimal value from 0-4095. VB0 is the minimum or .
DISCHARGE POWER SUPPLY MANUAL MODEL DC3005, MODEL 30010, MODEL 15012 OPERATION · SOURce:VOLTage or SOUR:VOLT Input the operating voltage. The de- sired operating voltage in volts follow either the long or short form of the command. A space can be inserted after the command, or the space can be omitted.
Page 17
DISCHARGE POWER SUPPLY MANUAL MODEL DC3005, MODEL 30010, MODEL 15012 OPERATION the above formula, 200 X 4095/300 = 2730 for model with a maximum voltage of 300 volts. • Input “VAxxxx” then press the enter key. Note: xxxx corresponds to a decimal number from 0-4095.
DISCHARGE POWER SUPPLY MANUAL MODEL DC3005, MODEL 30010, MODEL 15012 OPERATION Supply and the value of 2048 was returned from the terminal program. To convert this value to the output voltage, divide 2048 by 4095 and multiply by 300 volts for model DC30010 power supply.
Page 19
DISCHARGE POWER SUPPLY MANUAL MODEL DC3005, MODEL 30010, MODEL 15012 OPERATION Description Number Discharge Voltage Setpoint – Input 0 to 5 volts for 0 to maxi- mum discharge volts. Discharge Current Setpoint – Input 0 to 5 volts for 0 to maxi- mum amps of discharge current.
DISCHARGE POWER SUPPLY MANUAL MODEL DC3005, MODEL 30010, MODEL 15012 DIAGNOSTICS 4 DIAGNOSTICS 4.1 General The following information is intended to facilitate troubleshooting of the Dis- charge Power Supply. This information assumes that the Power Supply is con- nected to power and that all interconnects between power supplies and the ion source cable are made correctly.
Page 22
DISCHARGE POWER SUPPLY MANUAL MODEL DC3005, MODEL 30010, MODEL 15012 DIAGNOSTICS Help Code or Description Possible Causes and Corrective Error Message Action RS-232 Interface Serial Common Error. High Informational display only. No current fl owing in the action taken on unit operation.
DISCHARGE POWER SUPPLY MANUAL MODEL DC3005, MODEL 30010, MODEL 15012 LIMITED WARRANTY 5 LIMITED WARRANTY Kaufman & Robinson, Inc. (KRI) warrants to the purchaser or end user of the equip- ment it sells that such equipment will be free from defects in material and workman- ship under normal use and service.
DISCHARGE POWER SUPPLY MANUAL MODEL DC3005, MODEL 30010, MODEL 15012 SERVICE AND TECHNICAL INFORMATION 6 SERVICE AND TECHNICAL INFORMATION For technical information, repairs or replacement during Warranty, or repairs there- after, please contact: Kaufman & Robinson, Inc. 1330 Blue Spruce Dr.