Kaufman & Robinson DC3005 Manual

Kaufman & Robinson DC3005 Manual

Discharge controller/ discharge power supply

Advertisement

Quick Links

Kaufman & Robinson, Inc.
1330 Blue Spruce Drive
Fort Collins, Colorado 80524
Tel: 970-495-0187, Fax: 970-484-9350
Internet: www.ionsources.com
Copyright © 2011 by Kaufman & Robinson, Inc.
All rights reserved. No part of this publication
may be reproduced without written permission.
June 2011, Version 1
DISCHARGE CONTROLLER
MODEL DC3005
MODEL DC30010
MODEL DC15012

Advertisement

Table of Contents
loading

Summary of Contents for Kaufman & Robinson DC3005

  • Page 1 DISCHARGE CONTROLLER MODEL DC3005 MODEL DC30010 MODEL DC15012 Kaufman & Robinson, Inc. 1330 Blue Spruce Drive Fort Collins, Colorado 80524 Tel: 970-495-0187, Fax: 970-484-9350 Internet: www.ionsources.com Copyright © 2011 by Kaufman & Robinson, Inc. All rights reserved. No part of this publication may be reproduced without written permission.
  • Page 2: Table Of Contents

    DISCHARGE POWER SUPPLY MANUAL MODEL DC3005, MODEL 30010, MODEL 15012 CONTENTS Contents 1 GENERAL INFORMATION ................1-1 1.1 Introduction ..................... 1-1 1.2 Safety ..................... 1-1 1.3 Specifi cations ..................1-2 1.3.1 Dimensions ..................1-2 1.3.2 Weight .................... 1-2 1.3.3 AC Input ..................1-2 1.3.4 DC Output ..................
  • Page 3 DISCHARGE POWER SUPPLY MANUAL MODEL DC3005, MODEL 30010, MODEL 15012 CONTENTS Tables Table 1-1 Maximum Power, Voltage, and Output ..........1-3 Table 2-1 Inventory List..................2-1 Table 3-4 Analog connections................3-7 Table 3-4 Interlock connections................ 3-9 Table 4-1 Help codes and error messages for the Discharge Power Supply. .. 4-1 Figures Fig.
  • Page 4: General Information

    DISCHARGE POWER SUPPLY MANUAL MODEL DC3005, MODEL 30010, MODEL 15012 GENERAL INFORMATION 1 GENERAL INFORMATION 1.1 Introduction The Kaufman & Robinson, Inc. Discharge Power Supply is designed for use with a Kaufman & Robinson Ion Source. The intended use of this Power Supply is to provide DC voltage and current to the Ion Source Anode for ion production.
  • Page 5: Specifi Cations

    Continuous duty operation is specifi ed at 2000 watts up to 40˚C ambient air temperature. The maximum output for the DC3005 model of this Power Supply is 300 VDC and 5 amps. Operation at this level is limited by thermal protection.
  • Page 6: Table 1-1 Maximum Power, Voltage, And Output

    DISCHARGE POWER SUPPLY MANUAL MODEL DC3005, MODEL 30010, MODEL 15012 GENERAL INFORMATION Table 1-1 Maximum Power, Voltage, and Output Maximum Maximum Maximum Model Power Voltage Current 3005 1500 W 300 V 30010 2000 W 300 V 10 A 15015 2000 W...
  • Page 7: Inspection And Installation

    DISCHARGE POWER SUPPLY MANUAL MODEL DC3005, MODEL 30010, MODEL 15012 INSPECTION AND INSTALLATION 2 INSPECTION AND INSTALLATION This section describes how to install the Kaufman & Robinson, Inc., KRI® Dis- charge Power Supply which has been designed for operation of a KRI Ion Source.
  • Page 8: Rear Panel

    DISCHARGE POWER SUPPLY MANUAL MODEL DC3005, MODEL 30010, MODEL 15012 INSPECTION AND INSTALLATION selects between the output VOLTAGE, or CURRENT adjustment for the far right ecoder knob. The left display shows the Discharge voltage setpoint or readback in volts. The right display shows the Discharge current setpoint or readback in amps.
  • Page 9: Electrical-Connections To Ion Source And Discharge Power Supply

    DISCHARGE POWER SUPPLY MANUAL MODEL DC3005, MODEL 30010, MODEL 15012 INSPECTION AND INSTALLATION 2.4.3 Electrical-connections to ion source and discharge power supply Located on the back panel of the Power Supply are two sections of three con- nectors each for connecting the Discharge Power Supply directly to the ion source or through a KRI Filament Power Supply.
  • Page 10: Fig. 2-1 Discharge Power Supply Front Panel

    DISCHARGE POWER SUPPLY MANUAL MODEL DC3005, MODEL 30010, MODEL 15012 INSPECTION AND INSTALLATION Fig. 2-1 Discharge Power Supply front panel. _______________________________________________________________________ Copyright © 2011 by Kaufman & Robinson, Inc., 1330 Blue Spruce Drive, Fort Collins, CO 80524 Tel: 970-495-0187, Fax: 970-484-9350, Internet: www.ionsources.com...
  • Page 11: Fig. 2-2 Discharge Power Supply Rear Panel

    DISCHARGE POWER SUPPLY MANUAL MODEL DC3005, MODEL 30010, MODEL 15012 INSPECTION AND INSTALLATION RS-323 Remote Air vents Input Interlock Power Analog Ground Terminal Remote Positive Negative Terminal Terminal RS-485 Remote Fig. 2-2 Discharge Power Supply rear panel. _______________________________________________________________________ Copyright © 2011 by Kaufman & Robinson, Inc., 1330 Blue Spruce Drive, Fort Collins, CO 80524...
  • Page 12: Operation

    DISCHARGE POWER SUPPLY MANUAL MODEL DC3005, MODEL 30010, MODEL 15012 OPERATION 3 OPERATION The Discharge Power Supply can be operated in Local and Remote modes. Mode selection between Local and Remote modes is controlled using a Momentary Push Button located on the front panel of the Power Supply.
  • Page 13: Remote Mode Rs-232

    DISCHARGE POWER SUPPLY MANUAL MODEL DC3005, MODEL 30010, MODEL 15012 OPERATION given time. The load will determine the other. Example: If the Discharge set- points are 5 amps and 200 volts and the load is 25 Ohms then the output will be limited to 5 amps and the output voltage will be 5x25 = 125 volts according to Ohms law (V = IxR).
  • Page 14: Direct Rs-232 Connection From Computer To Discharge

    DISCHARGE POWER SUPPLY MANUAL MODEL DC3005, MODEL 30010, MODEL 15012 OPERATION control the Discharge Power Supply only. 3.2.1 Direct RS-232 connection from computer to discharge power supply The Discharge Power Supply can be operated from a host computer using an RS-232 port on the computer. Connection from the computer is made from a serial port on the computer to the serial port on the Discharge Power Supply, labeled, “RS-232”.
  • Page 15 DISCHARGE POWER SUPPLY MANUAL MODEL DC3005, MODEL 30010, MODEL 15012 OPERATION zero output, it also puts the unit in standby mode, while VA4095 is .. maximum output. • VBxxxx Sends a Voltage setpoint to the Discharge Power Supply. . Note: xxxx is a decimal value from 0-4095. VB0 is the minimum or .
  • Page 16: Operational Sequence

    DISCHARGE POWER SUPPLY MANUAL MODEL DC3005, MODEL 30010, MODEL 15012 OPERATION · SOURce:VOLTage or SOUR:VOLT Input the operating voltage. The de- sired operating voltage in volts follow either the long or short form of the command. A space can be inserted after the command, or the space can be omitted.
  • Page 17 DISCHARGE POWER SUPPLY MANUAL MODEL DC3005, MODEL 30010, MODEL 15012 OPERATION the above formula, 200 X 4095/300 = 2730 for model with a maximum voltage of 300 volts. • Input “VAxxxx” then press the enter key. Note: xxxx corresponds to a decimal number from 0-4095.
  • Page 18: Analog Input/Output

    DISCHARGE POWER SUPPLY MANUAL MODEL DC3005, MODEL 30010, MODEL 15012 OPERATION Supply and the value of 2048 was returned from the terminal program. To convert this value to the output voltage, divide 2048 by 4095 and multiply by 300 volts for model DC30010 power supply.
  • Page 19 DISCHARGE POWER SUPPLY MANUAL MODEL DC3005, MODEL 30010, MODEL 15012 OPERATION Description Number Discharge Voltage Setpoint – Input 0 to 5 volts for 0 to maxi- mum discharge volts. Discharge Current Setpoint – Input 0 to 5 volts for 0 to maxi- mum amps of discharge current.
  • Page 20: Table 3-4 Interlock Connections

    DISCHARGE POWER SUPPLY MANUAL MODEL DC3005, MODEL 30010, MODEL 15012 OPERATION Table 3-4 Interlock connections. Description Number Active Low Interlock – Connect to common (Interlock pin 2) to enable the Discharge Power Supply. Interlock Return – Common. _______________________________________________________________________ Copyright © 2011 by Kaufman & Robinson, Inc., 1330 Blue Spruce Drive, Fort Collins, CO 80524...
  • Page 21: Diagnostics

    DISCHARGE POWER SUPPLY MANUAL MODEL DC3005, MODEL 30010, MODEL 15012 DIAGNOSTICS 4 DIAGNOSTICS 4.1 General The following information is intended to facilitate troubleshooting of the Dis- charge Power Supply. This information assumes that the Power Supply is con- nected to power and that all interconnects between power supplies and the ion source cable are made correctly.
  • Page 22 DISCHARGE POWER SUPPLY MANUAL MODEL DC3005, MODEL 30010, MODEL 15012 DIAGNOSTICS Help Code or Description Possible Causes and Corrective Error Message Action RS-232 Interface Serial Common Error.  High Informational display only. No current fl owing in the action taken on unit operation.
  • Page 23: Limited Warranty

    DISCHARGE POWER SUPPLY MANUAL MODEL DC3005, MODEL 30010, MODEL 15012 LIMITED WARRANTY 5 LIMITED WARRANTY Kaufman & Robinson, Inc. (KRI) warrants to the purchaser or end user of the equip- ment it sells that such equipment will be free from defects in material and workman- ship under normal use and service.
  • Page 24: Service And Technical Information

    DISCHARGE POWER SUPPLY MANUAL MODEL DC3005, MODEL 30010, MODEL 15012 SERVICE AND TECHNICAL INFORMATION 6 SERVICE AND TECHNICAL INFORMATION For technical information, repairs or replacement during Warranty, or repairs there- after, please contact: Kaufman & Robinson, Inc. 1330 Blue Spruce Dr.

This manual is also suitable for:

Dc30010Dc15012

Table of Contents