anytronics Anyscene 512 Installation And Operation Manual

Scene recall unit

Advertisement

Installation and Operation Guide for the Anytronics Anyscene 512 Scene Recall Unit
This equipment should only be installed by competent electricians, the responsibility for safe
and correct installation of the system rests with the installer and these notes are intended only
for guidance.
1. Overview and Operation .............................................................................................. 2
2. Mounting ...................................................................................................................... 2
3. Power Supply & Connection ........................................................................................ 3
4. DMX Requirements ..................................................................................................... 4
4.1. DMX Loading ........................................................................................................................ 4
4.2. DMX Wiring .......................................................................................................................... 4
4.3. Line Bias Network ................................................................................................................ 4
4.4. DMX Backup ......................................................................................................................... 4
5. Multiple Anyscene 512 ................................................................................................ 5
5.1. Commissioning ..................................................................................................................... 5
6. Configuration ............................................................................................................... 6
6.1. Auto Cycle Mode ................................................................................................................. 8
6.2. Master / Speed Settings ....................................................................................................... 8
6.3. Fade Rate ............................................................................................................................. 9
6.4. Clearing All Memories .......................................................................................................... 9
7. Programming ............................................................................................................. 10
7.1. Single Anyscene 512 .......................................................................................................... 10
7.2. Multiple Anyscene 512 ...................................................................................................... 10
8. External Scene Control ............................................................................................. 11
8.1. Pre-July 2018 Models ......................................................................................................... 11
8.2. Post-July 2018 Models ....................................................................................................... 12
9. Specification .............................................................................................................. 13
Units 5 & 6 Hillside Industrial Estate
London Road, Horndean,
Hampshire, PO8 0BL
Tel +44 (0)23 9259 9410
Fax +44(0)23 9259 8723
Contents
Page 1 of 13
AT1039 Issue 1
Anyscene 512 Operating
Instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Anyscene 512 and is the answer not in the manual?

Questions and answers

Summary of Contents for anytronics Anyscene 512

  • Page 1: Table Of Contents

    Installation and Operation Guide for the Anytronics Anyscene 512 Scene Recall Unit This equipment should only be installed by competent electricians, the responsibility for safe and correct installation of the system rests with the installer and these notes are intended only for guidance.
  • Page 2: Overview And Operation

    The RJ45 sockets are on the back of the PCB along various option DIL switches and the connectors for the external scene recall control. The Anyscene 512 is also available with a reduced number of buttons for applications that require less than the standard number of scenes. These include a 4-button version...
  • Page 3: Power Supply & Connection

    The Anyscene requires a +5V DC supply capable of suppling up to 50 mA. When using multiple Anyscene 512 they should be linked together in series with each other and then linked to the receiving equipment. (Anytronics dimmers or the AS180) If used with other Anytronics equipment the required supply will be supplied through ...
  • Page 4: Dmx Requirements

    Anyscene 512 should have its line bias network set to ON. 4.4. DMX Backup With the power applied, the Anyscene 512 will power up and, if no input DMX data is detected within 2 seconds, it will start to output DMX data from the last used scene. If...
  • Page 5: Multiple Anyscene 512

    DMX data. After power up, the unit which was last in control of the system will restore the last selected scene (or auto cycle). If any normal DMX source is connected to the system, it will take over control of the system and force all the Anyscene 512 units into a standby/receive state.
  • Page 6: Configuration

    ON = 120R Terminator across the DMX line OFF = Terminator is not used Units 5 & 6 Hillside Industrial Estate Page 6 of 13 AT1039 Issue 1 London Road, Horndean, Anyscene 512 Operating Hampshire, PO8 0BL Instructions Tel +44 (0)23 9259 9410 Fax +44(0)23 9259 8723...
  • Page 7 ON = 120R Terminator across the DMX line OFF = Terminator is not used Units 5 & 6 Hillside Industrial Estate Page 7 of 13 AT1039 Issue 1 London Road, Horndean, Anyscene 512 Operating Hampshire, PO8 0BL Instructions Tel +44 (0)23 9259 9410 Fax +44(0)23 9259 8723...
  • Page 8: Auto Cycle Mode

    Pressing any of the scene select buttons will terminate the auto cycle mode, and the Anyscene 512 will fade to the selected scene. The unit will also exit auto cycle mode if an external DMX source becomes active.
  • Page 9: Fade Rate

    Power the unit whilst continuing to hold both buttons d) If this operation has been successful, the Data LED on the Anyscene 512 will light after approximately 4 seconds. It will cycle briefly on then off for 4 seconds until the Up and Down level buttons are released.
  • Page 10: Programming

    Press and hold the button on the Anyscene 512 where the current scene should be saved g) The Anyscene 512 data LED will flash twice to show the data has been saved. h) Repeat e) to g) for all required scenes Once all scenes have bee saved turn the MWP DILL ‘ON’...
  • Page 11: External Scene Control

    The Anyscene 512 also has the ability to use external isolated closing contacts to cycle round memories 1-7 in ascending sequence. The contacts should be connected to the two screw terminals on the back of the Anyscene 512 PCB, and the EXT DIL switch should be set to ON.
  • Page 12: Post-July 2018 Models

    Note: If the contact is held closed the Anyscene 512 will lock to the selected scene until the contact is reopened.
  • Page 13: Specification

    9. Specification Supply:  o +5 V DC via Category 5 DMX cable from Anytronics Dimmer or AS180 PSU Connections:  o DMX input/output via RJ45 connector o Data received from DMX addresses 1-512 o Data output to DMX addresses 1-512 o Low voltage closing contact input for external scene recall ...

Table of Contents