Page 1
R104 IMPORTANT NOTICE - FOR FIRE DOOR INSTALLATIONS REFER TO ITEM 1 IN FITTING INSTRUCTIONS • FOR USE WITH SIMONSWERK TE540, TE540FR & TE527 HINGES • A door holder/stop must be fitted • Should NOT be used with rising butt hinges.
PARTS LIST Fixing Plates Door Closer - x 1 Allen Keys - x 2 Screws - x 12 Allen Key for Extractor Bolt - x 1 Adjuster Screw (Locking) - x 1 CHECK ALL COMPONENT PARTS AGAINST PARTS LIST. TOOLS REQUIRED •...
IMPORTANT NOTICE DOOR CLOSERS FITTED TO A FIRE DOOR • Perkopower, conforms to Grade 3 of ANSI/BHMA A156-4 when the power latching action is set to maximum. • Turn adjuster screw fully to positive (+) as explained in 9. • Closer must be fitted no more than 30”...
Page 4
To achieve a maximum opening angle of 105° the closer must be installed within the constraints of fig. 2...
Page 5
FRAME PREPARATION FOR DOOR PREPARATION FOR FRAME PLATE BODY & DOOR PLATE For hollow metal frames, fixing brackets will need to be factory welded in place. Order item R199.XX NB To ensure correct operation of • Drill 4 x 1 1/16” Ø...
Page 6
INSTALLING CLOSER • Insert closer body into door. • Insert the Allen keys (C) through both top and bottom link rod holes. • Insert extractor bolt (E) into position and Both Allen keys must be correctly rotate clockwise until holes in link rods located appear.
Page 7
ADJUSTMENT - CLOSING SPEED • With the closer secure and now held • Remove dust cap. open by Allen keys, if necessary firmly push both link rods across door plate • Use one of the Allen keys (C) to and offer frame plate into frame void. adjust closing speed.
Page 8
Leopold Street Birmingham B12 0UJ, England T: +44 (0)121 772 2303 US Customer Service F: +44 (0)121 772 3334 Sales Office Direct Line: +44 (0)121 766 4200 usa@samuel-heath.com Federal I.D. No. 58-1504682 9-395-R104 www.samuel-heath.com/us Info@samuel-heath.com Issue: B www.samuel-heath.com / www.perkopower.com...