Page 1
R102 IMPORTANT NOTICE - FOR FIRE DOOR INSTALLATIONS REFER TO ITEM 1 IN FITTING INSTRUCTIONS • SUITABLE FOR USE WITH 4” WIDE HINGES TO GIVE MAXIMUM OPENING ANGLE OF 105° WHEN FITTED TO 1 3/4” DOOR. • A door holder/stop must be fitted •...
PARTS LIST Fixing Plates Door Closer - x 1 Template - x 1 Allen Keys - x 2 Allen Key for Screws - x 12 Extractor Bolt - x 1 Adjuster Screw (Locking) - x 1 CHECK ALL COMPONENT PARTS AGAINST PARTS LIST. TOOLS REQUIRED •...
IMPORTANT NOTICE DOOR CLOSERS FITTED TO A FIRE DOOR • Perkopower, conforms to Grade 3 of ANSI/BHMA A156-4 when the power latching action is set to maximum. • Turn adjuster screw fully to positive (+) as explained in 9. • Closer must be fitted no more than 30”...
Page 4
To achieve a maximum opening angle of 105° the center of the closer must be no more than 1 3/8” from the pivot point of the hinge. IMPORTANT To ensure the 1 3/8” distance is not exceeded the closer and fixing plate can both be offset in the door leaf and jamb (closer to the hinge pivot point) by up to a maximum of 1/4”...
Page 5
FRAME PREPARATION FOR DOOR PREPARATION FOR FRAME PLATE BODY & DOOR PLATE For hollow metal frames, fixing brackets will need to be factory welded in place. Order item R199.XX NB To ensure correct operation of • Drill 4 x 1 1/16” Ø...
Page 6
INSTALLING CLOSER • Insert closer body into door. • Insert the allen keys (C) through both top and bottom link rod holes. • Insert extractor bolt (E) into position and Both allen keys must be correctly rotate clockwise until holes in link rods located appear.
Page 7
ADJUSTMENT - CLOSING SPEED • With the closer secure and now held • Remove dust cap. open by allen keys, if necessary firmly push both link rods across door plate • Use one of the allen keys (C) to and offer frame plate into frame void. adjust closing speed.
Page 8
ADJUSTMENT - The Perkopower is protected by the POWER LATCHING ACTION following Patents and Applications. CANADA 2365822 2436363 HONG KONG 1038953 JAPAN 2000-602490 SINGAPORE 82862 TAIWAN 156554 6625847 2004/0111831 GB25447175 GB2415014 EP1605126 AUSTRIA BELGIUM DENMARK FRANCE GERMANY • The power latching action can be IRELAND adjusted using a plain flat ended EP1605126...