Download Print this page
Hussmann Impact CW2U-XGE Technical Data Sheet
Hussmann Impact CW2U-XGE Technical Data Sheet

Hussmann Impact CW2U-XGE Technical Data Sheet

Hussmann impact cw2u-xge merchandisers: data sheet
Hide thumbs Also See for Impact CW2U-XGE:

Advertisement

C
A
D
Item Part #
Description
F
A
T
AN
SSEMBLIES AND
HERMOSTATS
A. 6W Fan Assembly
0058698
Fan Motor, Evaporator
0142780
Fan Blade
embossing toward motor
B. 9W End Compartment Fan Assembly
0441479
Fan Motor, Standard
0377253
Fan Blade
embossing away from motor
C. 0398558
Standard Non-Adjustable
Defrost Thermostat
D. 0144732
Optional Adjustable
Refrigeration Thermostat
Note: Changed items have been underlined.
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
®
Merchandisers
H
C
Wiring Item #
E
G
F
Item Part #
L
B
AMPS AND
ALLASTS
E. 0376409
(1)
E. 0376410
F. 0135966
(2)
G. 0039764
(3)
H.
(4)
CW2U-XGE
Technical Data Sheet
P/N 0411395B
NSF
H
Description
Ballast, Electronic
2 lamps
Ballast, Electronic
3 lamps
Ballast, Electronic
1 lamp
(End Compartment)
Lamp Starter
Fluorescent Lamp
Replace with like fixtures
P/N 0411395B
®
Certified
April 2006
B
Wiring Item #
(5)
(5)
(6)
(7)
(8)

Advertisement

loading

Summary of Contents for Hussmann Impact CW2U-XGE

  • Page 1 C. 0398558 Standard Non-Adjustable Defrost Thermostat D. 0144732 Optional Adjustable Refrigeration Thermostat Note: Changed items have been underlined. HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. ® Wiring Item # Item Part # AMPS AND ALLASTS E. 0376409 E. 0376410 F.
  • Page 2: Plan Views

    Water seal outlet must clear front skid rail. Refrigeration Outlet Center of refrigeration outlet to O/S edge of front base rail RH end of case to center of refrigeration outlet 2 of 7 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. (257) (142) Base Rail Refrig. Outlet...
  • Page 3 18 in. Shelf COIL COIL (98) (35) (216) (1749) (2070) HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. CW2U-XGE Impact Unitized Convertible Island REFRIGERATION DATA Note: This data is based on store temperature and humidity that does not exceed 75°F and 55% R.H.
  • Page 4: Electrical Data

    Optional Lighting 2 Rows Canopy Optional Shelf Lighting 1 Row of Shelves 2 Rows of Shelves 3 Rows of Shelves 4 of 7 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. 8 ft 12 ft Amperes 90 in. 138 in. 1.76 2.76 1.28...
  • Page 5: Fan Wiring/Offtime Defrost

    Shelf Light Circuits Connector WARNING IRCLED NUMBERS ARTS Grayed components in 12 foot models only. = 120V N = Field G EUTRAL HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. 120V N EUTRAL Fan Wiring Offtime Defrost ROWN ROWN ROWN Defrost Refrigeration...
  • Page 6: Light Circuits

    All components must have mechanical ground, and the merchandiser must be grounded. R = Red Y = Yellow G = Green BL = Blue B = Black W = White 6 of 7 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. WARNING IRCLED NUMBERS ARTS Grayed components in 12 foot models only.
  • Page 7 Starter WARNING CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS Grayed components in 12 ft models only. = 120V N = 120V P OWER HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. SHELF LIGHT HARNESS Lamp Starter SHELF LIGHT HARNESS Lamp Starter SHELF LIGHT HARNESS...