Hussmann Impact C1CWCEI Technical Data Sheet
Hussmann Impact C1CWCEI Technical Data Sheet

Hussmann Impact C1CWCEI Technical Data Sheet

Prepackaged meat & delicatessen

Advertisement

Shown with
Standard
Light Bar
B
F
Item
Part #
Description
F
A
T
AN
SSEMBLIES AND
HERMOSTATS
A.
4W Fan Assembly
0392457
Fan Motor, Evaporator (MO.4410101)
0409511
Fan Blade (FB.0409511)
embossing toward motor
B.
0382028
Standard Non-adjustable
Defrost Thermostat (CT.0382028)
C.
0253451
Optional Adjustable
Refrigeration Thermostat
(CT.4480780)
Note: Revision A corrects illustration on Page 1 and plan view on Page 2.
©2006 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
®
Merchandisers
E
A
Wiring Item #
Location
Item
Part #
H
EATERS
D.
0401556
(1)
L
B
AMPS AND
ALLASTS
E.
0428648
(2)
F.
(3)
C1CWCEI
Technical Data Sheet
P/N 0454706_A
NSF
®
Bulb
March 2007
C
Description
Wiring Item #
Nosing Anti-Sweat Heater, 6 ft (4)
(HE.4850466)
Ballast, Electronic, 2 lamps
(BA.4480823)
Fluorescent Lamp
Replace with like fixtures
P/N 0454706_A
Certified
D
(5)
(6)

Advertisement

loading

Summary of Contents for Hussmann Impact C1CWCEI

  • Page 1 Refrigeration Thermostat (CT.4480780) Note: Revision A corrects illustration on Page 1 and plan view on Page 2. ©2006 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM ® Wiring Item # Item Part #...
  • Page 2: Plan Views

    Outside diameter of the drip pipe Refrigeration Outlet Back of case to center of refrigeration outlet Right-hand end of case to center of refrigeration outlet 2 of 6 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. Dimensions shown as inches and (mm). (1883) 34 (863) (216)
  • Page 3 NSF Certification These merchandisers are manufactured to meet ANSI /National Sanitation ® Foundation (NSF ) Standard #7 requirements. P/N 0454706_A HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM Dimensions shown as inches and (mm). (298) (1511) (1479) (849) COIL...
  • Page 4: Electrical Data

    230V 50Hz Export 208V Electric Defrost Heaters 208V Gas Defrost Heaters Standard Lighting Light Bar 1 Row 4 of 6 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. 6 ft Amperes 6 ft 0.62 6 ft 0.51 C1CWCEI Technical Data Sheet Watts...
  • Page 5 R = Red Y = Yellow G = Green BL = Blue B = Black W = White = 120V POWER = 120V NEUTRAL = FIELD GROUND = CASE GROUND P/N 0454706_A 5 of 6 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM...
  • Page 6 All components must have mechanical ground, and the merchandiser must be grounded. R = Red Y = Yellow G = Green BL = Blue B = Black W = White 6 of 6 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. Ballast Jumper Harness WARNING...