Cooperating Devices
MAX - optical probe for overflow
or maximal level.
OILER - thickness measurement of
fat, oil, mineral oil, organic,
petroleum substances.
SLUDO - detecting the sediment
layer in the separator or the
maximum level
Probes assembly
- Lower the sensor so that the measuring
point is at a exceeding level.
- Attach the sensor cable to the mounting
bracket NFIX.
- Use the COUPLER connector to lengthen
the cable
MAX sensor
The probe with a standard length of 5 m should
be hung on the FIX holder, which should be
placed directly under the manhole - preferably
in the inspection hole in the separator cover.
OILER sensor
The probe should be placed at the appropriate
depth / height and the sensor cable should be
wound around the mounting eye (FIX) in such
a way that the cable is blocked and the probe
does not change its position on the handle
during operation.
SLUDO sensor
The mounting height of the sensor depends on
the volume of the sludge in the separator. The
amount of accumulated sludge can not exceed
1/3 ÷ 1/2 of the height between the bottom of
the outlet pipe and the bottom of the tank.
When installing the sensor, it should be noted
that the deposit usually accumulates in the
measurement zone at different heights, which
depends mainly on the speed of the flowing
sewage. Where the flow velocity is the smallest, it will gather the most and vice versa.
Connect the probe with a 5 m standard cable to the holder. The handles should be
placed directly under the hatch - preferably in the inspection hole in the separator
cover.
SQUEALER-GSM
COUPLER-01
hermetic coupling
plug
NFIX-01 – set for
mounting
probe
CABLE-5, CABLE-10
– sensor extension
cable
– manual