To avoid problems in operating the unit, it is recommended to read this manual
thoroughly before using it. Do not interfere with construction or carry out
repairs yourself. Maintenance or repair work should be carried out by qualified
personnel (installer or company service). The manufacturer assumes no
responsibility for any damage resulting from improper assembly, malfunction
(device, software) or damage to the controller.
Description
SQUEALER controller is a modern microprocessor device for continuous monitoring
of the status of selected probes (MAX, OILER, SLUDO). The basic parameters of the
controller are 3 inputs, 3 relay output, LEDs indicating normal state, failure status and
alarm status, buzzer generating an alarm signal, alarm output, relay output, activated
at the time of alarm.
Front panel description
- LED lights continuously when the
power of the device is ON.
- the number of the LED flashes
indicates the GSM signal strength
(max. 4 flashes).
SQUEALER-GSM
The alarm module, powered by
- 3 inputs
230V, is used to measure and
- 3 output
control the level of the sludge
- PS 230V
layer, oil substances, grease,
- battery input
petroleum
overflow of the tank.
connected
and
properly set. Blinking LED indicates an
alarm sensor.
- The alarm is shown by the steady
light of the red LED + acoustic signal.
- A short press [<1] s button - delete
the buzzer alarm. Long press button
[> 2s]- clearing the alarm and restore the
relay to the state without an alarm.
- Checking the optical and acoustic
signals and relay outputs. Test can be
activated only when there is no alarm
sensors. Each time you press the button
activates / deactivates the function test.
– manual
substances
and
- LED lights when the
probe detects ALARM
- LED is ON constantly,
when the sensors are
the
dipswitches
are

Advertisement

loading

Summary of Contents for NOVABO SQUEALER-GSM

  • Page 1 SQUEALER-GSM – manual The alarm module, powered by - 3 inputs 230V, is used to measure and - 3 output control the level of the sludge - PS 230V layer, oil substances, grease, - battery input petroleum substances overflow of the tank.
  • Page 2 SQUEALER-GSM – manual Cooperating Devices MAX - optical probe for overflow COUPLER-01 – or maximal level. hermetic coupling plug OILER - thickness measurement of NFIX-01 – set for fat, oil, mineral oil, organic, mounting petroleum substances. probe SLUDO - detecting the sediment...
  • Page 3 Programming from PC a) visit WWW.NOVABO.COM b) install the driver for the USB cable: www.novabo.com >>> products >>> USB driver c) Install the NCONFIG program: www.novabo.com >>> products >>> Nconfig DIP SWITCH configuration DIP1 "ON" - SENSOR MAX active - probe 1 connected "OFF"...
  • Page 4 SQUEALER-GSM – manual Technical Data Supply voltage 230V Max. fuse 1.25A Power (nominal) 2.2 VA Output: NO/NC relays potential-free, 2A/120VAC or 2A/24VDC Ambient temperature -30°C ÷ +60°C Degree of protection IP 65 Dimensions without glands 187x122x90mm Cable glands M12, cable dimensions Ø 4.0-6.0 mm...