OSPZX20A-EN Instruction manual Pneumatic Actuated Butterfly Valve Z SP-1407 Please read this manual before installation and use. GENERAL It is small, light weight and economical butterfly valve. Actuator Double-acting type Single-acting type Threaded End Rc Socket End PSO (Airless SHUT) TAO (Airless SHUT) PSC (Airless OPEN) TAC (Airless OPEN)
OSPZX20A-EN VALVES SPECIFICATIONS Water Air, Gas Steam Chemicals Sea water Slurry Negative pressure Valve type Design 3 piece structure Connection Threaded End Rc Socket End Fluid Max pressure 1 MPa Size [mm] 015 to 050 Material Body SCS13A Disk SCS14A Socket - C-PVC Seat...
Page 3
OSPZX20A-EN PNEUMATIC ACTUATOR SPECIFICATIONS PND type Classification Double-acting type Actuator type PND-03S PND-03D PND-04D PND-05D Weight [kg] 0.2 Air consumption 0.05 0.08 0.19 0.35 (round-trip) Operation time [s] Less than 1. Operation SHUT by air to port A. OPEN by air to port B. Air pressure 0.4 to 0.7 MPa Piping connection...
Page 4
OSPZX20A-EN PNEUMATIC ACTUATOR SPECIFICATIONS TAD type Classification Double-acting type Actuator type TAD-040 TAD-050 TAD-063 TAD-080 TAD-100 TAD-125 TAD-160 Weight [kg] 0.9 18.2 Air consumption 0.11 0.18 0.34 0.66 1.36 2.72 5.56 (round-trip) Operation SHUT by air to port A. OPEN by air to port B. Air pressure 0.4 to 0.7 MPa Piping connection...
OSPZX20A-EN PNEUMATIC ACTUATOR SPECIFICATIONS OPTIONAL PARTS Classification Code PND PSO PSC TAD TAO TAC Speed Controller with bypass valve (Housing material: PPS) FR Unit (Regulator with Filter) TA2-FR (KONAN) Limit Switch Box (Standard load signal) Explosion Proof Limit Switch / VCX7001 (azbil) Ex d e II C T6 Speed Controller (with One-touch Fitting) One set Speed Controller (with One-touch Fitting) Two sets Speed Controller (with One-touch Fitting) Dual Speed Controller...
Page 6
OSPZX20A-EN PNEUMATIC ACTUATOR SPECIFICATIONS SOLENOID VALVE (Applicable Pneumatic Actuators: PND-05D / TAD / TAO / TAC) Classification ( : Voltage code) Code 5-port Solenoid Valve Lead wire 4N3S102K-L N43SL : Voltage Return 1 : 100V AC DIN Connector 4N3S102K-D N43SD (with bypass valve) 3 : 200V AC 5 : 24V DC...
OSPZX20A-EN INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS HANDLING & STORAGE AIR PIPING HANDLING • Pneumatic actuator has an air supply ports to operate Proper care in handling the valve should be taken to piston. prevent damage. Do not drop or throw it. STORAGE Double-acting type PORT A...
OSPZX20A-EN INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS OPERATION MANUAL OPERATION AIR SOURCE • Double-acting; stop the air supply and do not leave • Use the filtered dry air (less than 40 ). the air inside of cylinder. • Extra attention is needed where it's cold climate •...
Packing is from worn or valve stem distorted. For more information contact NIPPON VALVE CONTROLS, INC. for consultation. Document is subject to change without notice. 1-21-19 Meieki minami, Nakamura-ku, Nagoya 450-0003 JAPAN NIPPON VALVE CONTROLS, INC. TEL: 81-52-582-6435 FAX: 81-52-582-6439...