NIPPON VALVE CONTROLS Vpro BR Instruction Manual

Electric actuated ball valve
Hide thumbs Also See for Vpro BR:

Advertisement

Quick Links

Please read this manual before installation and use.
GENERAL
Flange-end ball valve and compact electric actuator.
Actuator
AM : For AC power.
AH1 : For AC power. (High speed)
DM : For DC power.
PAX : Proportional control.
Valve
BR type For various fluids and general use.
BS type For Wafer
VR type For control
GS type For Wafer. (JIS 10K / 20K)
PRODUCT CODE
BR type
(JIS 10K)
(JIS 20K)
BS type
VR type
(V-port)
(Reduced port)
GS type
(V-port)
(Full port)
(Standard port)
(1) Actuator
AM1 AM2 AH1
DM0 DM2 PAX
(2) Valve
BR BS VR
GS
(3) Voltage
1 : 100 / 110 V AC
2 : 200 / 220 V AC
0 : 24V DC
Instruction manual
Electric Actuated Ball Valve
B R
B R
B S
P A X V R
P A X V R
P A X G S
G S
G S
(1)
(2) (3) (4) (5) (6) (7) (8)
(4) Sizing code
(7) Ball material
0 : Standard
T : SCS13A
1 : Light
U : SUS316 / SCS14A
2 : Heavy
(8) Seat material
(5) Connection
F : F-PTFE
1 : JIS 10K
G : R-PTFE
3 : JIS 20K
R : R-F-PTFE
K : PEEK
(6) Body material
I : API
T : SCS13A
C : R-PEEK
U : SCS14A
M : SUS316 + Stellite
(9) Size [mm]
ex. 25 A ® 025
BR BS GS VR
BR / VR
1
-
3 T T
-
1
-
1 U U
-
1 U U
R 0 1 5 -
3 U U
V
3 U U
-
3 U U
R 0 4 0 -
(9)
(10) Option
AK : Aluminum alloy motor cover
M1 : Manual lever
C1 : Flexible cable
(11) Operation mode (PAX)
Nil : Mode A
1/13
OSCBR225-EN
BS
-
-
-
-
-
-
-
-
-
-
-
(10)
(11)
J : Mode B
SP-1474
GS

Advertisement

Table of Contents
loading

Summary of Contents for NIPPON VALVE CONTROLS Vpro BR

  • Page 1 OSCBR225-EN Instruction manual Electric Actuated Ball Valve BR BS GS VR SP-1474 Please read this manual before installation and use. GENERAL Flange-end ball valve and compact electric actuator. Actuator AM : For AC power. AH1 : For AC power. (High speed) DM : For DC power.
  • Page 2 OSCBR225-EN VALVES SPECIFICATIONS Water Air, Gas Steam Chemicals Sea water Slurry Negative pressure type Valve type Design 2-way, Full port 2-way, Wafer 2-way, V-port Connection JIS10K Flanged-end JIS20K Flanged-end JIS Flanges 10K JIS10K Flanged-end Fluid Max pressure 1 MPa 2 MPa 1 MPa 1 MPa Size [mm]...
  • Page 3: Pressure & Temperature Rating

    OSCBR225-EN VALVES SPECIFICATIONS Water Air, Gas Steam Chemicals Sea water Slurry Negative pressure type Valve type Design 2-way, Wafer Connection JIS Flanges 10K / 20K Fluid Max pressure 2 MPa Size [mm] 015 to 040 Material Body SCS14A Ball SCS14A (HCr PLTD) Seat R-PTFE PEEK...
  • Page 4 OSCBR225-EN ELECTRIC ACTUATOR SPECIFICATIONS type Actuator type AM1-030- AM1-070- AM1-180- AM2-030- AM2-070- AM2-180- ( :Voltage code) Voltage 100 / 110 V AC ±10 % 50/60 Hz (Voltage code: 1) 200 / 220 V AC ±10 % 50/60 Hz (Voltage code: 2) Rated torque [N m] 3 Operation time...
  • Page 5 OSCBR225-EN ELECTRIC ACTUATOR SPECIFICATIONS type Actuator type ( :Voltage code) AH1-030- AH1-070- AH1-180- Voltage 100 / 110 V AC ±10 % 50/60 Hz (Code: 1) 200 / 220 V AC ±10 % 50/60 Hz (Code: 2) Rated torque [N m] 3 Operation time [s] 3 / 2.5 (50/60 Hz) 6 / 5 (50/60 Hz)
  • Page 6 OSCBR225-EN ELECTRIC ACTUATOR SPECIFICATIONS type Actuator type DM0-030-0 DM0-070-0 DM0-180-0 DM2-030-0 DM2-070-0 DM2-180-0 Voltage 24 V DC Rated torque [N m] 3 Operation time [s] 0.8 to 1.5 2 to 3 4 to 6 2 to 3.5 2 to 3 4 to 6 Power consumption (Max) [VA]...
  • Page 7: Optional Parts

    OSCBR225-EN ELECTRIC ACTUATOR SPECIFICATIONS OPTIONAL PARTS Specifications Code No. DM Remarks Aluminum alloy motor cover Manual lever Detachable lever Flexible cable (Approx. 300 mm long) DIMENSIONS AH1 (030 / AM (030 / 070) DM2 (030) AM (180) DM (180) AH1 (180) (030) (070) 070)
  • Page 8 OSCBR225-EN ELECTRIC ACTUATOR SPECIFICATIONS type Actuator type ( :Voltage code) PAX-050- PAX-120- Voltage 100 / 110 V AC ±10 % 50/60 Hz (Code: 1) 200 / 220 V AC ±10 % 50/60 Hz (Code: 2) Rated torque [N m] 5 Operation time [s] 14 / 12 (50/60 Hz) 30 / 25 (50/60 Hz)
  • Page 9 OSCBR225-EN ELECTRIC ACTUATOR SPECIFICATIONS OPTIONAL PARTS Specifications Code No. PAX Remarks Aluminum alloy motor cover Flexible cable (Approx. 300 mm long) Operation SHUT by decreased signal « OPEN by Increased signal Mode A SHUT by increased signal « OPEN by decreased signal Mode B DIMENSION PAX (050)
  • Page 10: Installation

    OSCBR225-EN INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS HANDLING & STORAGE CAUTIONS FOR MAINTENANCE (GS) HANDLING Do not keep warm for maintenance of the valve Do not drop or throw the product as it may break. gland. STORAGE Store away from dust, moisture and direct sunlight. If possible, store in the original package.
  • Page 11: Operation

    OSCBR225-EN INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS CONTROL OPERATION AM1 / AH1 TESTING Control switch should be prepared one by one for • Make sure that power supply voltage is correct. Also actuator. Do not operate two or more actuator from check operating position, wiring, speed and signals.
  • Page 12: Manual Operation

    OSCBR225-EN INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS MANUAL OPERATION MAINTENANCE PRECAUTIONS • To prevent electric shock, be sure to turn off the • Manual operation should be a temporary operation. power when removing the actuator cover. • Be sure to turn off the power before manual •...
  • Page 13: Troubleshooting

    Stop in the Signal voltage Use a voltage source For more information contact mid position. source that can be made to NIPPON VALVE CONTROLS, INC. for consultation. (Input capacity flow more than 20 mA. signal’s shortage. Please contact us. 1 to 5 V.)