Strava 100.600 User Manual

Splint bath
Hide thumbs Also See for 100.600:

Advertisement

Quick Links

STRAVA
SplinT BATh
USeR MAnUAl
RE F 100.6 00 S tan d a rd Size
RE F 100.6 00 E
RE F 100.6 00 A
This manual must be given to the
user of the product. Before using this
product, this manual must be read and
saved for future reference.
Manufactured by:
Strava SolutionS
2733 Kanasita Drive #125
Hixson, TN 37343 USA
PA RT N UMB E R : 400. 600 Rev 3 S t rav a U se r M a n ua l
©C op yright 2020 S trava S olutions, LLC All rights rese rved

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 100.600 and is the answer not in the manual?

Questions and answers

Summary of Contents for Strava 100.600

  • Page 1 Manufactured by: Strava SolutionS 2733 Kanasita Drive #125 Hixson, TN 37343 USA PA RT N UMB E R : 400. 600 Rev 3 S t rav a U se r M a n ua l...
  • Page 2: Table Of Contents

    Troubleshooting Replacement parts Warranty/Replacements Service life Storage and handling Contact the Manufacturer product labeling © Co pyr i ght 2 02 0 Strava Sol ut io ns , L LC Al l ri ght s re se rv ed...
  • Page 3: Inspection

    300.107 Power Cord (Euro) REF 300.154 Power Cord (UK) REF 300.155 Power Cord (AU) REF 300.156 (do not use a detachable mains power cord with inadequate ratings to the Strava cord) 8 ft Drain Hose REF 200.101 Safety The safety section contains important information for the safe operation and use of this product. Read this information and any other safety information included with the product before using the splint bath.
  • Page 4: Symbols

    CAUTION! Caution indicates a potentially hazardous situation which, if not avoided, may result in property damage or minor injury or both. CAUTION! pag e : 4 © Copyr ight 2020 Strava S olutions, LLC All rights re se rve d...
  • Page 5 SYMBOL DESCRIPTION European Union CE mark. The CE mark indicates that this product satisfies the relevant requirements of EC Directives. Waste Electrical and Electronic Equipment (WEEE) This symbol on the product or on its packaging indicates that this product must not be disposed of with regular waste.
  • Page 6: The Purpose Of This Manual

    • Indications for Use The Strava Splint Bath is intended for use as a reservoir in hospitals, clinics and other medical facilities to heat and soften thermoplastic used in the splinting process. The device is intended for indoor use only.
  • Page 7: Product Description

    The water bath allows for thermoplastic splint sheets to be softened and made pliable to form to the body. The Strava Splint Bath has a custom LCD TOUCH display for accurate water temperature readings, user-controlled water temperature and time settings, thermoplastic sheet presets, user presets, sanitation cycles and automatic water drainage.
  • Page 8: Technical Data

    In case of spillage of hazardous materials on or inside the bath, operator must properly decontaminate the unit. pag e : 8 © Copyr ight 2020 Strava S olutions, LLC All rights re se rve d...
  • Page 9 Control Panel 1 – Ta rget te mp erature display 2 – Ac t ua l temp erature disp lay 3 – Temp e rat ure display m o d e ° C/ °F 4 – Tim e co nt rol up or d own 5 –...
  • Page 10: Instructions

    • Note: Sanitation cycle defaults to “on”. pag e : 10 © Copyr ight 2020 Strava S olutions, LLC All rights re se rve d...
  • Page 11 • Sanitation cycle – Strava Solutions highly recommends daily sanitation of the splint bath. The sanitation cycle factory default is “on”. The unit is set to engage in a nightly sanitation cycle at 8:00pm (20:00 hrs) Sunday through Thursday.
  • Page 12 Note: audio can be shut off except on certain error message screens. • Factory reset – CAUTION! by clicking reset, all factory defaults will be restored and all user-defined presets will be erased. pag e : 12 © Copyr ight 2020 Strava S olutions, LLC All rights re se rve d...
  • Page 13 Once the bath is empty, proceed with tank cleaning. Cleaning the bath: • Strava recommends a minimum of a monthly water reservoir cleaning (more frequently if conditions warrant it) • Turn the power switch off and unplug the unit from the wall receptacle.
  • Page 14: Troubleshooting

    Mains Power Cord (Euro Hospital Grade) REF 300.154 Mains Power Cord (UK Hospital Grade) REF 300.155 Mains Power Cord (AU Hospital Grade) REF 300.156 Hose REF 200.101 pag e : 14 © Copyr ight 2020 Strava S olutions, LLC All rights re se rve d...
  • Page 15: Warranty/Replacements

    Under normal use and following all guidelines defined in this manual, Strava splint baths are warrantied for a period of one year from when product is received. Should replacement or repair be required, purchaser must notify dealer or manufacturer in writing.
  • Page 16: Product Labeling