Symptom
Compressor will not start
cuts out on overload
Problem
Light's won't start
Light's flicker
Ballast hums
This HGM case was manufactured in Gloversville, New York. Our phone #'s are (518) 725-
0644 for NY state residents, and toll free 800-753-7790 or outside NY. Any questions not
covered in this manual, please call the factory.
TROUBLE SHOOTING CON'T
Probable Cause (s)
1. Low voltage
2. Defective compressor
3. Defective relay
4. Restriction or moisture
5. Inadequate air over con-
denser
6. Defective condenser fan
motor
Trouble Shooting Lighting System
1. Check light switch
2. Check continuity to ballast
3. Check to see if bulbs inserted properly into
socket
4. Check voltage
1. Allow lamps to warm up
2. Check lamp shield for cracks
3. Check sockets for moisture and proper
contact
4. Bulb replacement may be necessary
5. Check voltage
6. New bulbs tend to flicker until used
1. Check voltage
2. Replace ballast
Page 10
Possible Solution (s)
1. Contact electrician
2. Replace
3. Replace
4. Leak check, replace drier,
evacuate and recharge
5. Clean condenser
6. Replace
Solution

Advertisement