Page 2
4” Plastic impeller and diffuser Submersible Deep Well Pumps ST series ORIGINAL OPERATING INSTRUCTIONS 1.Symbols used in this manual Warning If these safety instructions are not observed , it may result in personal injury! If these safety instructions are not observed , it may result in malfunction or damage to the equipment! Caution Notes or instructions that make the job easier and ensure safe operation.
Page 3
The following components must be installed in the delivery pipe : A pressure gauge ; A check valve at max. 7m from the pump outlet and more lift-type check valves (5), depending on the type of installation ( at least on every 50m in the straight vertical pipe above the pump ), to provide protection against water hammering ;...
Page 18
Description Photo Description Photo Description Photo Discharge Stop ring Casing Valve Strainer Cable guard casing Valve Suction in- O-ring cone terconnector Valve Pump shaft/ retaining O-ring coupling ring Adapter Shaft retain- Screw ring ing ring Diffuser Shaft sleeve Washer Bowl Shaft sleeve Bearing Impeller...
Page 19
TROUBLE SHOOTING CHART Problem Possible Cause of Trouble & Remedy Pump will not run. 1. No power. Replace fuses or reset circuit breaker. Contact electrician if required. 2. Incorrect voltage. Contact electrician if necessary. 3. Incorrect fuses. Replace with proper fuses. 4.
Need help?
Do you have a question about the ST Series and is the answer not in the manual?
Questions and answers