MANUAL PERIBEST I12 – I17 – I21 Safety information Symbols In this manual the following symbols are used: WARNING Procedures which, if not carried out with the necessary care, may result in serious damage to the hose pump or in serious bodily harm.
MANUAL PERIBEST I12 – I17 – I21 Immediately contact your PeriBest representative, if you noticed a potential danger while using your hose pump. WARNING The user of the hose pump is always fully responsible for observing the local valid safety regulations and directives.
MANUAL PERIBEST I12 – I17 – I21 Safety instructions Live parts · The device must be disconnected from the power supply before it is opened · Isolate damaged faulty or manipulated devices from the mains in order to de-energise. Emergency stop switch An emergency stop switch is to be connected for the entire plant.
Page 8
MANUAL PERIBEST I12 – I17 – I21 · Do not carry out any maintenance operations or dismantle the pump without first making sure that the pipes are not under pressure and are empty or isolated. · As the peristaltic pump is volumetric and its functioning is positive displacement, it is necessary to prevent a possible overload of pressure, due to for example, the accidental closure of a valve.
If parts are used that are not PeriBest Pumps S.L. (hereafter called PeriBest) parts, every warranty becomes void. Damaged parts which are covered by the applicable warranty conditions can be returned to the manufacturer.
Identification of the pump PeriBest pumps are identifiable by a smart NFC label located on top of the pump. On the label you can find the serial number, and a NFC device and QR code, that allow to acces to all information about the pump trough a mobile device.
MANUAL PERIBEST I12 – I17 – I21 Pump construction 1: Cover 2: Rotor 3: Hose 4: Pump housing 5: Base plate 6: Gear reducer 7: Motor Pump Hose 1: Extruded inner layer 2: Two High density textile layers 3: Smooth grinded external layer...
Page 12
MANUAL PERIBEST I12 – I17 – I21 The pump hose liner material should be chemically resistant with the product to be pumped. Dependent on the specific requirements of your application a corresponding pump hose must be selected. For each pump model various hose types are available. The material of the inner liner of the pump hose determines the hose type.
0,15 0,22 Gear Box The pump models I12, I17 and I21, uses worm gear reducer. The lubrication of these gear reducers is for life and are totally free of maintenance. Electric motor The motors supplied are standard IEC motors with B5 flange.
MANUAL PERIBEST I12 – I17 – I21 Transport, storage and elevation Transport The pump is protected by a wooden box. All packing materials are recyclable. The pump may be transported on storage position with one roller unassembled. Check before operate the pump.
MANUAL PERIBEST I12 – I17 – I21 Installation Unpacking and Inspection When unpacking carefully follow the instructions as given on the packaging or on the hose pump. Check that your delivery is correct and check it for any transport damage. Report any damage immediately to your PeriBest representative.
MANUAL PERIBEST I12 – I17 – I21 OVERPRESSURE Consider the maximum permissible working pressure on the discharge Side. Exceeding the maximum working pressure may lead to serious damage to the pump. Maximum connection loads Make sure that the maximum forces on the connections are not exceeded:...
MANUAL PERIBEST I12 – I17 – I21 Comissioning Testing prior to commissioning the pump Ensure that the pump has not been damaged during transportation or storage. Immediately report any damage to the supplier. Check that the mains voltage is suitable for the motor.
MANUAL PERIBEST I12 – I17 – I21 Maintenance General WARNING Disconnect the pump from the mains. You may only carry out work on the pump after it has previously been switched off and disconnected from the mains. In case the motor is fitted with a frequency controller and has a single-phase power supply, wait two minutes to make sure that the capacitors have discharged.
MANUAL PERIBEST I12 – I17 – I21 Changing lubricant. After every 2nd hose change or after 5,000 service hours, whichever comes first or after hose rupture. Replacing pressing rollers. Wear on the running surface. Replacing bearings. If necessary. Cleaning hose The inside of the pump hose can be easily cleaned by rinsing the pump with clean water.
MANUAL PERIBEST I12 – I17 – I21 8. Remove the press flange and connections from the pump housing 9. Remove the pump hose to be exchanged Fitting pump hose 1. Clean the interior surfaces of the pump housing 2. Check the rollers. Ensure that the roller surfaces are not damaged 3.
MANUAL PERIBEST I12 – I17 – I21 Troubleshooting Problem Possible cause Solution Pump hose has no lubricant Lubricate pump hose Increased pump Increased product temperature Reduce product temperature temperature Insufficient poor suction Check suction line for blockages conditions Pump speed too high...
Page 23
MANUAL PERIBEST I12 – I17 – I21 lifetime High pump speed Reduce pump speed the hoses High conveying temperature Reduce product temperature High operating pressure Reduce operating pressure Pump cavitation Check the suction conditions Abnormal elevation Check rollers shaft mounting...
Company responsible for manufacturing and commercializing the below specified machine: PERISTALTIC PUMP Industrial range models: I12, I17, I21, I28, I35, I43, I55 Declare under our sole responsibility: Its conformity in accordance with all applicable provisions of the Machinery Directive (2006/42/EC), Low Voltage...