Wallace Pumps MULTISAN PRO Installation And Servicing Instruction Manual

Wallace Pumps MULTISAN PRO Installation And Servicing Instruction Manual

Automatic toilet and waste water collection tank and electrically operated macerator pump system

Advertisement

MULTISAN-PRO 
Automatic toilet and waste water collection tank and electrically operated macerator pump system.
INSTALLATION AND SERVICING INSTRUCTION MANUAL
PLEASE READ ALL INSTRUCTIONS PRIOR TO PROCEEDING WITH ANY WORK
A permit may be required. Check with the plumbing, drainage and/or electrical inspectors before installation.
Local regulations may stipulate additional installation requirements.
You must consult with your local plumbing and drainage inspector for a permit approval.
AFTER INSTALLATION, THE INSTALLER MUST HAND THIS MANUAL TO THE OWNER
FOR THE PROPER OPERATION AND MAINTENANCE OF THE MULTI-SAN
Failure to do so will result in the installer being made liable under the current legislation for any future claims
Congratulations on your purchase of Multisan-Pro wastewater package pump. For this product to meet its
expected lifetime please ensure it is installed by a qualified technician and follow the maintenance
schedule as detailed in section 13.2. Please keep a record of by whom and when the maintenance was
PAGE INDEX
Section
3. Product overview ..................................... 5
4. Applications ............................................. 5
5. Features & benefits .................................. 6
6. Pump hydraulic capability............................6
7. Warning: for your safety .......................... 7
8. List of fittings supplied & extra may require.7
Limitations: We reserve the right to change these instructions and improve the product without prior notice.
AUCKLAND
55 MAURICE RD, PENROSE
PO BOX 12 387
PH
09 622 9100
FAX 09 622 9119
G:\INSTRUCT\MULTISAN PRO\Multisan Pro Instructions 251119.docx Page 1
resulting from any incorrect operation or servicing.
completed, that need to be provided to us when asked for.
WELLINGTON
PH 027 543 8634
 
 
 
Section
9. Alarm & solenoid valve system.....
11. Pump Operational Logic...............................10
12. Specific Installation (High Temp/remote).10/11
13. Care and servicing......................................11
14. Warranty & Limitations............................12
15. Fault Finding chart ...................................12/14
16 Spare parts drawing & list..........................15/19
7/8
CHRISTCHURCH
35 BUCHAN ST
SYDENHAM
PH
03 365 6453
FAX 03 366 6995

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MULTISAN PRO and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Wallace Pumps MULTISAN PRO

  • Page 1: Table Of Contents

    G:\INSTRUCT\MULTISAN PRO\Multisan Pro Instructions 251119.docx Page 1       MULTISAN‐PRO  Automatic toilet and waste water collection tank and electrically operated macerator pump system. INSTALLATION AND SERVICING INSTRUCTION MANUAL PLEASE READ ALL INSTRUCTIONS PRIOR TO PROCEEDING WITH ANY WORK A permit may be required. Check with the plumbing, drainage and/or electrical inspectors before installation.
  • Page 2 G:\INSTRUCT\MULTISAN PRO\Multisan Pro Instructions 251119.docx Page 2 Figure 1: Dimensions Figure 2: Cut-away view Cut-away view through the cover showing the dry mounted pump and motor unit, mounted on a sealed gas and water-tight collection tank, and the pan connection on the side of the tank.
  • Page 3: General View And Connections

    If both are connected, each must have its own valve. The extra connection can be purchased from Wallace Pumps if required. This connection is 100 mm centre height from the base floor level. The inlet pipe must be properly braced to prevent the water pressure from dislocating the push-fit connection.
  • Page 4 2. TYPICAL WASTE WATER CONNECTION DRAWING WITH SHOWER TRAY/BATH WASTE HEIGHT Refer below typical connections shown connected to pump unit. If in doubt please call Wallace Pumps for further details. Shower Tray or Bath Waste Height: Refer above schematic drawing.
  • Page 5: Product Overview

    For complete household or commercial duties refer to our Wallace Pumps Sanipower, Saniboy or Sanistar range of packaged pump stations. The WALLACE MULTISAN-PRO collects the gravity fed waste liquid into its collection tank. When a set water level is reached, the micro pressure switch inside the collection tank automatically activates the powerful quiet pump equipped with a cutter blade and an open impeller to deliver the effluent under pressure to the desired location through a 32 mm internal diameter pipe.
  • Page 6: Features & Benefits

    -This graph is based on a flow of 35 litres /min. If flows exceed 35 L/min please contact Wallace Pumps for assessment. -Measure the overall height of the delivery pipework (from the bottom of the tank to the highest point in the delivery line, also referred to as Static Head).
  • Page 7: Warning: For Your Safety

    1 x Special 40mm DWV pipe connection with “one way check valve” for connecting shower or bath waste water pipe. If above additional fitting is required can be purchased from Wallace Pumps 2 x Special 40mm DWV pipe fittings with one end spigot (connecting to pump) & other end socket to connect waste pipe from WHB, Sink, or any other domestic appliance and to connect 40mm DWV pipe as vent connection if required as per local rules and regulations.
  • Page 8 G:\INSTRUCT\MULTISAN PRO\Multisan Pro Instructions 251119.docx Page 8 Optional Alarm System with automatic water shut off system via Solenoid Valve may require as per local rules and regulations. Please Check!!! Wiring Diagram & connection details for “Water Monitor” used as “Alarm” and / or water shut off system via “Solenoid Valve/s” and / or “Washing M/C turn off”...
  • Page 9: General Installation Aspects & Electrical Data.9

    G:\INSTRUCT\MULTISAN PRO\Multisan Pro Instructions 251119.docx Page 9 10. GENERAL INSTALLATION ASPECTS AND ELECTRICAL DATA 10.1 General 1. Where a permit is required, it is required that the unit should be installed by a registered plumber and the power supply should be connected by a registered electrician.
  • Page 10: Pump Operational Logic

    Refer in next page typical remote installations. These May be possible with Multisan-Pro unit. However, please contact Wallace Pumps explain your situation and get approval before remote installing the unit. Any issues with pump by remote installation Without Prior approval from Wallace will make Warranty NULL...
  • Page 11: Care And Servicing

    Also ensure no liquid will flow into it during servicing. 13.3 Modifications or Repairs: Wallace Pumps does not warrant for any damage to the unit or any other property caused by any un-authorised modifications/repairs in contravention with the Company's instructions or by use of materials or fittings not...
  • Page 12: Warranty & Limitations

    & records as per clause 12.2 page 11 of this manual, Wallace Pumps warrants the unit for a period of 2 years from the date of purchase, against defects in materials and workmanship on the basis of return to our distributor's or service agent's premises, freight paid.
  • Page 13 G:\INSTRUCT\MULTISAN PRO\Multisan Pro Instructions 251119.docx Page 13 Motor does not start - Discharge pipe is blocked. - Check that pipe is clear, check that non- at all and alarm return valve is operational. activates - Pump is blocked. - Turn off the power and check that the pump...
  • Page 14 G:\INSTRUCT\MULTISAN PRO\Multisan Pro Instructions 251119.docx Page 14 Liquid leaks from -Loose pipework connection. -Tighten the pipework connections. the unit. -Faulty liquid level switch. -Check and replace if required. -Mechanical seal fault (leakage between -Check and replace if necessary. motor and pump).
  • Page 15: Spare Parts Drawing & List

    G:\INSTRUCT\MULTISAN PRO\Multisan Pro Instructions 251119.docx Page 15 16. Spare Parts drawing & list pump unit...
  • Page 16 G:\INSTRUCT\MULTISAN PRO\Multisan Pro Instructions 251119.docx Page 16 Complete lifting unit...
  • Page 17 G:\INSTRUCT\MULTISAN PRO\Multisan Pro Instructions 251119.docx Page 17 Circuit board...
  • Page 18 G:\INSTRUCT\MULTISAN PRO\Multisan Pro Instructions 251119.docx Page 18 assembly drawing nomination Article numb assembly 10525 Assembly unit complete Microboy E3 lifting unit 181902 Assembly unit complete Microboy E3 pro 1.10/1.20 Container MICROBOY; complete without pump and 117620 switching device 1.120 O-ring 30x3 117703 1.140...
  • Page 19 07/10/ 2014 Multi-San Instructions Page 19 Baugruppen Pos.-Nr.: Stückza Bezeichnung Artikelnummer assembly: pump 2.100 Ball bearing 6202 270017 2.110 Compensating disk 24x35x0,5 continuation 270018 2.120 Shaft seal 12x26x7 117125 2.130 Mechanical seal bonnet 270921 2.140 Mechanical seal bottom section 270021 2.160 Impeller Microboy 272905...

Table of Contents