PRODUCT USE DESCRIPTION / IMPORTANT SAFETY INSTRUCTIONS P R O D U C T U S E D E S C R I P T I O N The Oakworks PT Tables are used to support the patient during examinations and procedures. They are intended to be operated by a healthcare professional in a medical environment.
Page 5
IMPORTANT SAFETY INSTRUCTIONS Proper operation of this equipment is very important for the safety of the operator, patient, and any other individuals in the area of this equipment. Directions for use of this equipment are described in this manual. The operator should read these sections carefully. Weight Limit: (patient and accessories) 550 lbs.
PRODUCT DESCRIPTION PT100 Upholstered Top Wheels (2) Single 24v motor with cover Foot Control Steel Scissor-style Optional Dual Self-locking powder-coated base Locking Casters molded rubber with dual crossbeams (1) feet (2) STANDARD SPECIFICATIONS Height Range Powered 16”-34” (40-86 cm.) Foot Control Height Motion Table Voltage Options 120V/60Hz or 230V/50Hz...
PRODUCT DESCRIPTION PT150 Manual Lift-Assist Back Rest control Upholstered Top Seat section with In- tegrated Face Rest Steel Scissor-style powder-coated base with dual crossbeams (1) Single 24v Motor with cover Self-locking molded rubber feet (2) Wheels (2) Foot Control Optional Dual Locking Casters STANDARD SPECIFICATIONS Motion 1...
PRODUCT DESCRIPTION PT200 Upholstered Top Articulating Head Rest Section with Adjustable Face Rest Cushion & Insert Pad Single 24v Motor with cover Manual Control for Back Rest Top Wheels (2) Self-locking Foot Control molded rubber Steel Scissor-style feet (2) powder-coated base with dual crossbeams (1) Optional Dual Locking Casters...
PRODUCT DESCRIPTION PT250 Upholstered Top Articulating Head Rest Section Self-locking molded rubber feet (2) Manual Control for Steel Scissor-style Articulating Head Rest powder-coated Section base with dual crossbeams (1) Single 24v motor Foot Control with cover Wheels (2) Optional Dual Locking Casters STANDARD SPECIFICATIONS Motion 1...
PRODUCT DESCRIPTION PT300 Manual Lift-Assist Back Rest control Articulating Head Rest Section Optional Dual Locking Casters Steel Scissor-style powder-coated base with dual Foot Control crossbeams (1) Single 24v Manual Control for motor with cover Articulating Head Rest Wheels (2) Section STANDARD SPECIFICATIONS Motion 1 Powered 16”-34”...
PRODUCT DESCRIPTION PT400 Electrically Controlled Center Break Manual Lift-Assist Back Rest control Articulating Head 24v motor Rest Section Optional Dual Locking Casters Steel Scissor-style powder-coated base with dual Foot Control crossbeams (1) Single 24v motor with cover Manual Control for Wheels (2) Articulating Head Rest Section...
PRODUCT DESCRIPTION PT400M Electrically Controlled Center Break 29.5” Self-locking 11” molded rubber feet (2) QuickLock Plat- form & Boiance Face Pad Steel Scissor-style powder-coated 21.5” base with dual cm.) crossbeams (1) Foot Control 77” 22” (56 cm.) Wheels (2) (196 cm.) Single 24v motor with cover...
PRODUCT DESCRIPTION Orthopedic Hi-Lo Casting Table Upholstered Top Gas Assist Control for Backrest Retractable side rail Self-locking Resin casting molded rubber cover feet (2) Manual Control for Articulating Casting Section Single 24v motor Optional Dual with cover Locking Casters Steel Scissor-style powder-coated base with dual crossbeams (1) Wheels (2)
INSTALLATION The Tables come completely assembled and ready to use. Plug the cord into a functioning outlet that is rated for the table. (See Grounding below) Arrange the power cord and control cords so that they will not create a tripping hazard and where the controls are located to your liking and are conveniently accessible.
DIRECTIONS FOR USE C O N T R O L O P E R A T I O N S - A L L T A B L E S (E X C E P T P T400 & P T400M) CAUTION Be sure the self-locking molded rubber feet are flat side down to ensure safety and stability.
DIRECTIONS FOR USE F O O T C O N T R O L O P E R A T I O N S - P T400 & P T400M T A B L E S O N L Y CAUTION DO NOT sit or stand on the articulating head rest section.
Page 17
DIRECTIONS FOR USE H A N D C O N T R O L O P E R A T I O N S - P T400 & P T400M T A B L E S O N L Y CAUTION DO NOT sit or stand on the articulating head rest section.
DIRECTIONS FOR USE A D J U S T I N G T H E B A C K R E S T S E C T I O N CAUTION Do not sit on the Backrest section. Back Rest Control TO RAISE THE BACKREST: TO LOWER THE BACKREST:...
DIRECTIONS FOR USE A R T I C U L A T I N G H E A D R E S T U S E CAUTION Do not sit or stand on the articulating head rest section. Do not use Head Rest Section in assisting the client on or off the table.
DIRECTIONS FOR USE P T400M - R O T A T I N G A R M R E S T S U S E Be sure to install the arm rest on the Screw the Arm Rests into the pre- Adjust the Arm Rests as needed for correct side of the table.
DIRECTIONS FOR USE M O V I N G T H E T A B L E CAUTION Before moving any of the Tables, disconnect the power cord from the power outlet. The table weighs as much as 200 lbs. (91 kg.) Use extreme caution when lifting the table to move it. Two people are required to move the table safely.
DIRECTIONS FOR USE Q U I C K L O C K F A C E R E S T CAUTION Do not put excessive weight or pressure on the Quicklock Face Rest. Do not extend the dowels of the Quicklock Face Rest 3” (7.6 cm.) from the Fowler (Backrest) section. Double articulating action provides nearly limitless positioning options with the QuickLock Face ™...
CLEANING & DISINFECTION R E C O M M E N D E D C L E A N E R S/D I S I N F E C T A N T S DANGER To reduce the risk of electric shock: - Always unplug this furnishing from the electrical outlet before cleaning.
INSPECTIONS / WARRANTY I N S P E C T I O N S RECOMMENDED REGULAR INSPECTIONS (monthly or local standard) • Check for damage to the power, hand control(s) and foot control(s) on all cables. • Visually inspect components for obvious damage that could cause problems during operation. RECOMMENDED PERIODIC INSPECTIONS (yearly or local standard) •...
MODEL NUMBER & SERIAL NUMBER P T S E R I E S The model number and serial number are located on the underside of the foot section. Model Serial Number Number 16796025 PXSLA3311873ACTTVN Ser#: PXR563146 US G2 30 x 22-38 x 72 3M/TT/2S TTSKYBLUE 01/04/2013 Order#:654321 Notes: Sample Product Label Model Numbers and Serial Numbers always start with a letter.
SPECIFICATIONS Guidance and manufacturer’s declaration - electromagnetic emissions The table is intended for use in the electromagnetic environment specified below. The customer or the user of the table should assure that it is used in such an environment. Emissions Test Compliance Electromagnetic environment - guidance The table uses RF energy only for its internal...
SPECIFICATIONS Guidance and manufacturer’s declaration - electromagnetic immunity The table is intended for use in the electromagnetic environment specified below. The customer or the user of the table should assure that it is used in such an environment. Electromagnetic Immunity Test IEC 60601 test level Compliance level environment - guidance...
Page 29
SPECIFICATIONS Guidance and manufacturer’s declaration - electromagnetic immunity The table is intended for use in the electromagnetic environment specified below. The customer or the user of the table should assure that it is used in such an environment. Electromagnetic Immunity Test IEC 60601 test level Compliance level environment - guidance...
USER MANUAL OAKWORKS ® PT Tables C O N T A C T I N F O R M A T I O N: Oakworks Inc. ® 923 East Wellspring Road New Freedom, PA 17349 Phone: 717.235.6807 FAX: 717.235.6798 www.oakworksmed.com 3034177 CONFORMS TO: ANSI/AAMI STD ES60601-1...