Regent Control Systems BC-9461 Operating Manual

Length counter

Advertisement

OPERATING MANUAL
LENGTH COUNTER
BC 9461/7461
Model
Display
Size(HXWXD)
Panel Cutout
Output
Power Supply
Sensor
Memory
Protection Level
(As per request)
Operating
Temperature
Relative
Humidity
MICRO SWITCH:- M/S Connection 7 & 9
230V AC
!
50Hz, 4VA
RELAY
NO
C
NC
L
N
1
2
3
4
5
Helpline : +91 9624004123
1 2 3 4 5 .6
TOTAL
1 2 3 .4
BATCH COUNT
SET
ENT
REGENT CONTROL SYSTEMS (I) PVT LTD.
BC 9461

Technical Specification

BC-9461
UPPER:- 6 Digit 7 seg 0.56",
red LED Display
LOWER:- 4 Digit 7 seg 0.4",
green LED Display
96 X 96 X 45 mm
92 X 92 mm
Proximity PNP/NPN (Selectable) & Micro Switch
IP-65(Front side) AS per IS/IEC 60529:2001
Connection Diagram
12 11
-
+
BUZZER
R
CARE
REGENT CONTROL SYSTEMS (I) PVT LTD
MADE IN INDIA
+12V
NPN PNP GND
I/P
I/P
RST
6
7
8
9
10
REGENT CONTROL SYSTEMS
BC 9461
R
RESET
1 Relay, 1C/O,230V AC,5A
230V AC, 50 Hz, Approx 4VA
Nonvolatile
0°C To 55°C
Up to 95% RH Non Condensing
15
16
17
L
1
+12V
230V AC
50Hz,4VA
N
2
NPN
!
3
R
PNP
CARE
4
REGENT CONTROL SYSTEMS (I) PVT LTD
GND
MADE IN INDIA
MICRO SWITCH:-
M/S Connection 9 & 11
5
6
RESET
BUZZER
7
-
18
19
20
Page - 1
BC 7461
1 2 3 4 5 .6
TOTAL
1 2 3 .4
BATCH COUNT
SET
RESET
ENT
REGENT CONTROL SYSTEMS (I) PVT LTD.
BC 7461
BC-7461
UPPER:- 6 Digit 7 seg 0.4",
red LED Display
LOWER:- 4 Digit 7 seg 0.4",
green LED Display
72 X 72 X 60 mm
68 X 68 mm
8
I/P
9
I/P
10
11
12
Note:
NC
1. For NPN Proxi Short pin 3 & 4
Proxi Connction to 4,6,5
13
C
2. For PNP Proxi Short pin 6 & 5
Proxi Connction to 3,4,5
14
NO
3. For Microswitch Short pin 6 & 5
Micro switch Connection to 3 & 4
R
MADE IN INDIA

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BC-9461 and is the answer not in the manual?

Questions and answers

Summary of Contents for Regent Control Systems BC-9461

  • Page 1 1 2 3 4 5 .6 1 2 3 .4 TOTAL 1 2 3 .4 BATCH COUNT BATCH COUNT RESET RESET REGENT CONTROL SYSTEMS (I) PVT LTD. REGENT CONTROL SYSTEMS (I) PVT LTD. BC 9461 BC 7461 Technical Specification Model BC-9461 BC-7461 UPPER:- 6 Digit 7 seg 0.56”,...
  • Page 2 Key Operation 1) Press Key to go next parameter. 2) Release the Key, to save the set point. 3) Press Key for manual reset of total length Ch -1 For Program 1 2 3 4 5 6 Total Batch Count 1 2 3 4 Batch Count Press...
  • Page 3 Working Ch -1 * When set Count reaches at set value ,Relay and Buzzer will be ON. * Relay will stay on up to the set Time. * After completion of the set Time - both ,Relay and Buzzer will be OFF. * If the set time is then Instrument will work in manual mode and user need to press Reset key to turn OFF Relay &...
  • Page 4 0 1 2 3 BATCH COUNT 96mm 96mm 92mm 92mm 42mm DIMENSIONS RESET REGENT CONTROL SYSTEMS (I) PVT LTD. 95mm - 3.75 inches BC 7461 MODEL 1 2 3 4 5 .6 TOTAL 1 2 3 .4 72mm 72mm 68mm...

This manual is also suitable for:

Bc-7461

Table of Contents