6.0 cu. ft. capacity duradrum electric dryer
Hide thumbs Also See for DuraDrum HTDX100EM:

Advertisement

Quick Links

Side View
HTDX100EM – Hotpoint
Dryer Dimensions (in inches)
23-1/2
25-3/4
25-1/2*
5-1/4
Side View
* 24-1/2" from the edge of the side panel to the front.
25-1/2" from front to edge of end caps.
HTP Washer/Dryers XLC QSart
Specification Created 7/10
470157
Rear View
6.0 cu. ft. capacity DuraDrum
®
27
42
11-1/2
36
2
2-1/2
Rear View

electric dryer

Exhaust Options:
4-way via rear, right, left and bottom.
Circuit Requirements:
An individual, properly-grounded branch circuit, protected by a
30-amp circuit breaker or a time-delay fuse, is required.
Electric Dryer Rating:
240V, 5600W, 60Hz, 24 Amp
208V, 4400W, 60Hz, 22 Amp
Installation Information: For complete information, see installation
instructions packed with product for current dimensional data.
Special Installation Requirements
Alcove or Closet Installation:
• If your dryer is approved for installation in an alcove or closet, it will be stated on a
label on the dryer back.
3-1/2
• The dryer MUST be exhausted to the outside.
• Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:
0" either side
3" front and rear
• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52".
• Closet doors must be louvered or otherwise ventilated and must contain a minimum of
60 sq. in. of open area equally distributed. If this closet contains both a washer and a
dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed.
• No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
Bathroom or Bedroom Installation:
• The dryer MUST be exhausted to the outdoors.
• The installation must conform with the local codes, or in the absence of local codes,
with the National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.
Minimum Clearances other than Alcove or Closet Installation:
• Minimum clearances to combustible surfaces
0" both sides
3" rear
Listed by
Underwriters
Laboratories

Advertisement

loading
Need help?

Need help?

Do you have a question about the DuraDrum HTDX100EM and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hotpoint DuraDrum HTDX100EM

  • Page 1: Electric Dryer

    Special Installation Requirements Alcove or Closet Installation: • If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back. 3-1/2 •...
  • Page 2 For complete information, see installation instructions packed with your dryer. Ducting Materials: For best performance, this dryer should be vented with 4" diameter all rigid metal exhaust duct. If rigid metal duct cannot be used, then UL-listed flexible metal (semi-rigid) ducting can be used (Kit WX08X10077).
  • Page 3 • Reverse-a-Door - Door opening can be reversed to meet laundry room needs • Upfront lint filter - With placement of the lint filter in the front of the dryer, air flow is optimized through the drum, and access to the filter simplifies cleaning •...