Connecting the TSM-PM to USB Interface Adapter ............14 Data Output ..........................17 See the Serial Data Stream ....................17 Serial Data Format ........................ 17 Custom Delimiters (New with Firmware Update 2.0) ............. 18 Error Codes ........................... 18 Release Date 21 July 2022 Anemoment LLC...
Page 6
Symptom: The TSM Sensor data is not clear or is all “99’s”..........36 Updating TSM Sensor Firmware .....................36 Updating TSM Sensor Bootloader ..................36 WARRANTY AND DISCLAIMER ....................31 Limited Warranty........................31 Warranty Returns ........................31 Limitation of Liability ......................31 LISTS OF FIGURES AND TABLES ....................33 Release Date 21 July 2022 Anemoment LLC...
TriSonica™ Mini Flat Base Starter Kit includes one each: TSM-FB, USB-Adapter, and USB A-to-B cable. 7. TSM-PMSK TriSonica Mini Pipe Mount Starter Kit includes one each: TSM- PM, USB-Adapter, USB A-to-B Cable, and 2-meter single terminated cable. As used in this Manual, the term “TSM Sensor” means the information presented applies to both the TSM-FB and the TSM-PM.
Screenshots and photos can be extremely helpful! Limitation Alerts Anemoment wants you to get the best possible use from your TSM Sensor investment, and we understand that each User has a unique idea they want to create. You know best what you are trying to accomplish.
It is up to the User, however, to interpret this data in the User’s unique situational context, which may require combination with additional User-provided data or other post-processing. Anemoment is not responsible for such additional data or processing. Electro-Mechanical Motors and Magnetic Sensors Electro-mechanical motors generate magnetic fields;...
UNCTIONAL HARACTERISTICS Sampling Frequency Maximum 40 Hz Ultrasonic Frequency 60 KHz ± 5KHz This rating applies to units with S/N M00841 and later. Earlier TSM Sensors’ supply voltage was 9 – 32 VDC. Release Date 21 July 2022 Anemoment LLC...
User Warnings For safety purposes, use batteries or LPS power supply certified with local standards; Anemoment is not responsible for any harm or safety issue caused by supplying the product with uncertified batteries, power supplies or circuits.
Page 12
TSM Sensor is properly sealed and that glue bonds are intact between each pillar and the top and bottom bodies, and conduct calibration and function tests before returning TSM sensor to use. Release Date 21 July 2022 Anemoment LLC...
The User-supplied mounting platform should be a flat plate having a 5-mm hole in the center for the connecting wires, and 5.5-mm hole positioned at the Gore-Tex™ Vent to allow for water vapor and air pressure exchange. Release Date 21 July 2022 Anemoment LLC...
TSM-FB Tripod Mounting Plate Anemoment offers an optional 3d-printed mounting plate for attaching the TSM-FB to a standard platform or camera tripod. This mounting plate features a brass ¼-20 threaded insert. TSM-PM The TSM-PM has a circular connector to mount over a standard ½”...
The TSM-PM contains a female 12 Pin circular connector that connects to a male 12 Pin Circular IP67 connector. Pre-made cables with connectors may be purchased from Anemoment in 2m, 5m, 10m, and 20m lengths. Customized cables and mating connectors may be purchased directly from Samtec.com (see https://www.samtec.com/products/mcp for...
: Because the cable contains 12 wires designed AUTION to accommodate the multi-protocol capable TSM-PM, do not match these color assignments the labels printed on the USB Adapter circuit board. A helpful video demonstrating this connection is available at Anemoment.com/resources/. Release Date 21 July 2022 Anemoment LLC...
EIA232 or LVTTL-UART mode with the LACK settings of 115200,8,N,1 regardless of the software settings of the instrument. IGHT 3.3V LVTTL-UART Serial Data Output. REEN Ground connection. See the description for Pin #2 Release Date 21 July 2022 Anemoment LLC...
Page 18
Release Date 21 July 2022 Anemoment LLC...
TSM Sensor and allows data pass-through, the Serial Data Stream from the TSM Sensor can be viewed by using a Terminal Emulator app such as Tera Term or with the TriSonica Mini User App downloadable at https://anemoment.com/resources/.
Figure 8: Example of Custom Delimiters in use Error Codes When the TriSonica Mini firmware detects an error, it outputs an error code in the data stream in all the affected parameters. All error codes appear in the format of “-99.x”. The decimal value of the error code varies with the error type.
If no User input is received after the Serial Menu has been inactive for one minute, the Sphere returns to sampling mode and any changes made are not stored in the non- volatile memory. Release Date 21 July 2022 Anemoment LLC...
Parameters shown within square brackets “[“ and “]” are optional. NOTE: We intend to make the TSM CLI self-documenting, so with future Firmware Releases, the detailed help for each command may differ from Release Date 21 July 2022 Anemoment LLC...
Page 23
You can download the current Firmware Release Notes at Anemoment.com/Resources. Release Date 21 July 2022 Anemoment LLC...
Tag, Untag, and Decimal Commands section in this document. levelcalibrate YES Start a level calibration cycle. (Not available on TSM- See the section of this document for LEVEL CALIBRATION more details about the level calibration procedure. Release Date 21 July 2022 Anemoment LLC...
Page 25
OMMANDS version Displays software version and build numbers wd540 [<value>] Set or Show the Wind Direction 540 Degree Mode See the Horizontal Wind Direction 540 Degree Mode section in this chapter. Release Date 21 July 2022 Anemoment LLC...
Page 26
Release Date 21 July 2022 Anemoment LLC...
Sets or shows the low power configuration parameters. Low power mode can be woken internally, or externally. Do not use the external wake mode on a TSM-WWS. Release Date 21 July 2022 Anemoment LLC...
Page 28
North, and positive V as being from the West. The “otsm” setting matches the original TriSonica Mini output definition of positive U as being form the North, and positive V as being from the East. paramdelim [<delim> | space]...
“}” indicates the end of the command. When the close curly brace “}” is received the command is executed and the results returned within the curly braces. This is not compatible with the JSON protocol. Release Date 21 July 2022 Anemoment LLC...
When the wind direction crosses 360 or 0 degrees the Sphere software shifts 7 to 180-to-540 mode. The Sphere stays in the 180-to-540 mode until the wind direction again crosses either 180 or 540, which causes the Sphere to return to 0-to-360-mode. Release Date 21 July 2022 Anemoment LLC...
If after making changes to Non-Volatile Memory the User wants to restore the permanently saved parameters to their original default values, this restore can be done by using the command factoryrestore [YES] in the expert menu mode. Release Date 21 July 2022 Anemoment LLC...
TSM into as many orientations as possible using a three-dimensional figure eight pattern. Enter “nvwrite” to store the values in non-volatile memory. Release Date 21 July 2022 Anemoment LLC...
Page 34
Before leaving our facility, each TriSonica Mini undergoes calibration to identify that exact distance for each acoustic path. We do this by locking down the TriSonica Mini in a zero-airflow chamber fitted with an independent temperature and humidity sensor.
The average of the ultrasonic temperature is used to calculate the humidity from the dew point. An issue seen during testing occurred when the TriSonica Mini was removed from a warm 90% humidity environment to a cooler 30% environment. The quick change caused condensation inside the unit and it displayed humidity greater than 100% until the condensation evaporated and equalized through the vent.
Page 36
Release Date 21 July 2022 Anemoment LLC...
If those are wired correctly, make sure that you have correctly connected the wire to a UART input (such as on a Raspberry-PI, Arduino, BeagleBone or the like). Fix any mis-wired connections you have found. Release Date 21 July 2022 Anemoment LLC...
Please power down the TSM Sensor, and then restart. Updating TSM Sensor Firmware The User can download the latest Firmware release at Anemoment.com/resources/ and save the program in the Download directory. Connect the TSM Sensor that computer. From this point, choose a method of command access. (TeraTerm is offered as the Terminal...
Product damaged due to improper installation or use. Anemoment’s sole obligation under this Warranty shall be to repair, replace, or refund purchase price of the applicable Product, at its sole option, provided that Anemoment is given timely notice of the defect.
Page 40
Release Date 21 July 2022 Anemoment LLC...
Page 41
Table 5: TSM-PIN DESCRIPTION & CABLE WIRE COLORS ............15 Table 6: SERIAL MENU FUNCTIONS ................... 20 Table 7: Serial Commands in the Command Line Interface ............22 Table 8: Serial Commands In Expert Mode ................25 Release Date 21 July 2022 Anemoment LLC...
Page 42
Release Date 21 July 2022 Anemoment LLC...
Need help?
Do you have a question about the TriSonica Mini and is the answer not in the manual?
Questions and answers