Download Print this page

Advertisement

Quick Links

FOCUS HMI PLC USER MANUAL

Advertisement

loading

Summary of Contents for Focus HMI Basic

  • Page 1 FOCUS HMI PLC USER MANUAL...
  • Page 2: General Features

    Modbus TCP / IP Slave feature. Bidirectional read-write can be done. If the number of serial ports is not enough, you can expand it with a USB serial port. Focus HMI is one of the very few HMIs with quad-core. Page transitions and communication are extremely fast with a 1.2 GHz processor.
  • Page 3 Focus HMI PLC USER MANUAL There are also models of the Focus HMI with integrated Fulmatic 7 PLC. The integrated PLC has a maximum of 40 IO. It can be expanded up to 16384 IO capacity with Fulmatic 7 Remote IO modules.
  • Page 4 Focus HMI PLC USER MANUAL B. USAGE AND SAFETY STANDARD FEATURES FOR ALL MODELS WITH PLC Power 24 V DC %15 tolerance band 2,4 W Power Consumption (standby) Digital Input / Output 8 x 200 kHz Digital Input 8 x 655 kHz 0,1 A Digital Input...
  • Page 5 Focus HMI PLC USER MANUAL Security Notes PLC must be de-energized before wiring. Wiring must be done in accordance with the connection diagram. Sections of the cables that connect to terminals should be taken into consideration. The cables to be connected must be used by stripping them to the point where they can enter into the terminal.
  • Page 6 Focus HMI PLC USER MANUAL C. BACK VIEW AND TERMINAL DESCRIPTIONS Connection PX-XXXX01-XX PX-XXXX02-XX Description Description Point +24 V Terminal Supply +24 V Terminal Supply 0 V Terminal Supply 0 V Terminal Supply COM0 A Endpoint COM0 A Endpoint COM0 B Endpoint...
  • Page 7 Focus HMI PLC USER MANUAL Connection Point Description PLC Run/Stop Button Socket PLC 10/100M Full Duplex Ethernet Connection Point Green LED Ethernet Link LED Yellow LED Ethernet Communication LED +24 V Terminal Supply 0 V Terminal Supply Ground Endpoint COM0 A1 / TX1 Endpoint...
  • Page 8 Focus HMI PLC USER MANUAL Connection Description Point Run LED +24V LED +5V LED ---- COM0 A LED COM0 B LED ---- COM1 A LED COM1 B LED ---- Power on LED Run LED Fault LED COM0 A1 / TX1 LED...
  • Page 9: Technical Specifications

    Focus HMI PLC USER MANUAL D. TECHNICAL SPECIFICATIONS Scannig Time: The scanning time varies according to the size of the program, the blocks and functions used in the program the input-output types and operations used. You can see the real time and maximum scan times in the Speed PLC program’s PLC Status section.
  • Page 10 Focus HMI PLC USER MANUAL Rising Edge Directional Counter: When this type is selected, the next input is automatically assigned as the direction identifier. When logic 0 is applied to the direction identifier input, the counter moves in the negative direction, and when the logic 1 is applied, it moves in the positive direction.
  • Page 11 Focus HMI PLC USER MANUAL ABZ Encoder 2x: When ABZ type 2x Encoder is selected, the A endpoint of the Encoder should be connected to the pin where the selection was made, B endpoint should be connected to the next input and Z pin should be connected to the next input.
  • Page 12 Focus HMI PLC USER MANUAL Period Rising and Falling Edge: It is the input type for measuring the period length. The measurement is found by calculating the time difference between the rising edge or falling edge and the subsequent falling or rising edge in the signal. The measurement is made in microseconds.
  • Page 13 Focus HMI PLC USER MANUAL 2 Wire Transmitter Connection 3 Wire Transmitter Connection 4 Wire Transmitter Connection Fultek Kontrol Sistemleri San. Ve Tic. Ltd. Sti. Address: Buyuksehir Mah. Cumhuriyet Cad. Ekinoks E2 Blok K:2 D:8 Beylikduzu / ISTANBUL Phone: +90 212 871 0128 / Email: info@fultek.com.tr / Web site: www.fultek.com.tr...
  • Page 14 Focus HMI PLC USER MANUAL Use of Analog Inputs 2 Wire PT100 Connection 3 Wire PT100 Connection 4 Wire PT100 Connection Use of Analog Inputs Fultek Kontrol Sistemleri San. Ve Tic. Ltd. Sti. Address: Buyuksehir Mah. Cumhuriyet Cad. Ekinoks E2 Blok K:2 D:8 Beylikduzu / ISTANBUL...
  • Page 15 Focus HMI PLC USER MANUAL Two Channel Loadcell Single Channel Loadcell Analog Inputs se of Single Channel Loadcell Connection: + Excitation -- V1 + Signal -- AI4 - Signal -- AI5 - Excitation -- GND Two Channel Loadcell Connection: 1.Loadcell 2.Loadcell...
  • Page 16 Focus HMI PLC USER MANUAL Digital Outputs: There are 8 x 655 kHz 0.1 A and 8 x 20 kHz 0.5 A Digital Outputs. Use of Digital Outputs PWM Output: Hardware PWM (Pulse Width Modulation) is a function that allows to control the supplied electricity by changing the logic 1 residence times of generated square wave a certain frequency.
  • Page 17 Focus HMI PLC USER MANUAL The frequency is 10 times the value written to this variable. The period is a cycle of frequency. The %tON setpoint that controls the PWM logic high state can be at a maximum resolution of 16 bits (between 0-65535) depending on the frequency. When the frequency increases, the resolution decreases.
  • Page 18 Focus HMI PLC USER MANUAL Analog Outputs: There are two outputs, 0-10V from the AQ0 analog output channel and 0-20mA from the AQ1 analog output channel. The analog output refreshing period is equal to the operation cycle of the PLC module.
  • Page 19: Other Features

    Focus HMI PLC USER MANUAL E. OTHER FEATURES Modbus Communication: Modbus RTU ve Modbus TCP ile haberleşmeyi desteklemektedir. 5 connections can be provided simultaneously with Modbus TCP. Up to 32 devices can be connected with the Modbus RTU from each serial port.

This manual is also suitable for:

Hmi plusHmi professional