Trufrost YC-150EW Operation Manual

Trufrost YC-150EW Operation Manual

Ice lined refrigerator

Advertisement

Quick Links

ICE LINED REFRIGERATOR
OPERATION MANUAL
YC-150EW
WHO/PQS certificate report No.1911-16528-WB-19-331
PQS Independent type-testing protocol: WHO/PQS/E003/RF03-VP.3
PQS performance specification: WHO/PQS/E003/RF03.4
Issuing date: 2020.3.25
Version: C
Trufrost Cooling Pvt. Ltd.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the YC-150EW and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Trufrost YC-150EW

  • Page 1 ICE LINED REFRIGERATOR OPERATION MANUAL YC-150EW WHO/PQS certificate report No.1911-16528-WB-19-331 PQS Independent type-testing protocol: WHO/PQS/E003/RF03-VP.3 PQS performance specification: WHO/PQS/E003/RF03.4 Issuing date: 2020.3.25 Version: C Trufrost Cooling Pvt. Ltd.
  • Page 2 Better science, Better life! www.trufrostbiomedical.com info@trufrost.com...
  • Page 3: Table Of Contents

    Content 1. Introduction....................................4 2. Precautions for Safe Operation ...............................5 3. Precautions for Use...................................7 4. Installation ....................................7 4.1 Installation environment:............................7 4.2 Installation site:................................8 4.3 Preparation before use ..............................8 4.4 First initial starting................................8 4.5 Operation after power failure............................9 5.
  • Page 4: Introduction

    1. Introduction Dear Customer: Thank you for choosing Trufrostbiomedical products! For your personal safety and better performance of this unit, please read this Operation Manual thoroughly and save it properly for future reference. User can copy some chapters of this operation manual, such as instructing users how to deal with emergencies, but only for internal use.
  • Page 5: Precautions For Safe Operation

    2. Precautions for Safe Operation For the first time to use this device, please read the following warning labels very carefully, to use the equipment safely and correctly. CAUTION: CAUTION. failure to observe the precautions may Failure to observe the precautions may result in serious personal injury or result in personal injury, equipment death.
  • Page 6 Be sure to install the unit on a sturdy floor, no shaking and tilting. Please do not place the equipment in a dangerous area, do not run the equipment near flammable materials to prevent explosion or fire accidents. Do not place the equipment in the sun or rain area, to prevent short circuit or overheating and other dangerous accidents.
  • Page 7: Precautions For Use

    Please pay attention not to turn the equipment over, when moving it, to prevent equipment damage or personal injury. It should be lifted from the bottom when carrying it, and the inclined surface should not be greater than 45 degrees. Please pay attention to personal safety when carrying, to avoid harm to human or surroundings. 3.
  • Page 8: Installation Site

    There is no direct sunlight and no other cold and heat sources and strong electromagnetic  interference, which will affect the normal operation of the control system and directly damage the system in severe cases. 4.2 Installation site: This unit is a precision machine. When select a location to install this unit, keep the following conditions for perfect performance: It should not be installed in a small confined space, the door of the room should not be less than ...
  • Page 9: Operation After Power Failure

    4.Check whether the temperature reaches the required value, and then observe the equipment for more than 24 hours. After confirming the normal performance, a small amount of items can be placed in the storage room. 5.Try not to open the door in the cooling process, otherwise the temperature will rise. 4.5 Operation after power failure 1.The equipment has memory function for the setting value.
  • Page 10: Refrigerator Components

    5. Refrigerator Components Hinge Door Display panel Handle Cabinet Casters Power switch Outfall Battery switch * Due to the improvement of the products and different models, the actual products may be different from the schematic diagram. The figure above is for reference only! * Structure and composition: the product is composed of box body, door body, refrigeration system and control system.
  • Page 11 light Locked Keyboard lock indicator light dark Unlocked 1.Control instruction is a digital temperature display window. Under normal operating conditions, it will ① display the real-time temperature inside the cabinet, the unit is °C; in the setting state, different prompt characters can be displayed (see below for details); :...
  • Page 12: Function Setting

    If the item is too damp or too dry, it will affect the humidity change in the cabinet. It is better to keep the articles sealed. 6.2 Function setting: 1. Parameters setting: Suggestion value Item Value range Remarks YC-150EW 0~50 Compressor start delay (min) 0~24 Time to power failure (hours) 0~10 Temperature setting (℃) 1~25 Return difference setting (℃)
  • Page 13: Maintenance

    Control sensor short circuit or open circuit Ambient temperature sensor out of range Ambient temperature sensor below lower range limit Low battery 7. Maintenance Caution For personal safety, please cut off the power supply before any maintenance!  Don't inhale medications or aerosols around the device while maintaining the equipment, or ...
  • Page 14: Disposal

    ① Regarding to the units which are not in the operation for a long time.It is better to make products running for more than 24 hours per month to charge to prolong the service life of the battery. ② If the equipment is not used for a long time, it should be regularly (usually once a month) turned on power and opened the power supply switch lock to run and charge, with not less than 24 hours each time.
  • Page 15: Condensation Draining

    7.6 Condensation Draining After using the product for a period of time, there may be condensed water formed at the bottom of the chamber, please drain away the condensed water in time to avoid damaging the storage items such as vaccines. ①...
  • Page 16: After-Sale Service

    Special No. Size 890041897 5*20 5A/250V 8. After-sale Service Any product has the possibility of failure. Please observe the operation of the medical refrigerator in the process of use. If there is any abnormality, please check and compare the errors with the following table.If you can't fix the issue, Please inform our service center in time.
  • Page 17: Specifications

    Main performance data: Temperature Thermal Cooling Energy consumption (stable runing, Zone Model Power cycle insulating performance intermittent power) performance YC-150EW Tropic (Hot) 1~3 days 8h/day 20~25h 0.934kWh/24h Energy consumption Energy consumption (cool Model Lining Refrigerator vaccine (stable runing, continuous down)
  • Page 18: Wiring Diagram

    11. Wiring diagram Object / part No. Manufacturer/ Type / model Technical data Mark(s) of conformity trademark Jiangsu Willtron Tech ZYD-4P-25 220-240 V, 50/60 Hz, 25/4 W, VDE 40031795+ Co.,Ltd 0.19 A tested with appliance Compressor Wanbao Group FTK55X 220-240 V, 50/60 Hz, R290 VDE 40051763 Compressor Co., Ltd.
  • Page 19 scope is exceeded, please take proper measures to mitigate this risk and ensure the safe transportation for the products. The packing materials of the products do not contain ozone-depleting substances under the “Montreal Protocol”. Product packaging is designed to comply with export regulations and to fully protect equipment for transport by air, sea or land to any area of the world, including remote areas with poor weather and storage conditions and high humidity.
  • Page 20: Warranty Certificate

    (Instructions) Dear users: Thank you for using Trufrost pharmacy refrigerators, blood bank refrigerators, ice lined refrigerators, medical freezers, ULT freezers and other medical and scientific research equipment. Our company will comply with the relevant provisions of the "Three Guarantees Regulations"...
  • Page 21 Pasting receipt Dear users Thank you for choosing Trufrost brand products! Please fill out this card and send it back to our company. We will establish the user file for you in time.
  • Page 22 Marketed globally by: TRUFROST COOLING PRIVATE LIMITED 1215, 12th Floor, Tower B, Emaar Digital Greens, Golf Course Extn. Road, Sector 61, Gurugram – 122011 T. +91-7303166766 info@trufrost.com www.trufrostbiomedical.com...

Table of Contents