SATO KEIRYOKI Sigma-II NS II-Q Quick Start Manual

SATO KEIRYOKI Sigma-II NS II-Q Quick Start Manual

Thermohygrograph

Advertisement

Quick Links

Model NS
-Q
NS
  - S
COMPONENTS
●  
1. Carrying handle
2. Pen arm for temperature
3. Cartridge pen
4. Recording cylinder
5. Pen lifting bar
6. Pen lifting lever
7. Acrylic Cover
8. Bracket
9. Fine adjustment screw for
temperature
10. Pen arm for humidity
11. Fine adjustment screw for
humidity
12. Temperature sensor
(Bimetal strip)
13. Venthole
Thermohygrograph

Advertisement

loading
Need help?

Need help?

Do you have a question about the Sigma-II NS II-Q and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SATO KEIRYOKI Sigma-II NS II-Q

  • Page 1 Ⅱ Model NS Thermohygrograph Ⅱ   - S COMPONENTS ●   ① ⑦ 1. Carrying handle 2. Pen arm for temperature 3. Cartridge pen ⑧ ② 4. Recording cylinder 5. Pen lifting bar ⑨ 6. Pen lifting lever 7. Acrylic Cover ⑩...
  • Page 2 Thank you for purchasing the Sigma II Thermohygrograph. ・   This instrument is designed to measure and record the indoor temperature and humidity. Do not use it for other purposes. ・   Read this manual thoroughly before use and keep it in a safe place for future references. This product is strictly inspected and securely packed at shipment, however the indicated value may shift due to excessive shock or vibration during transportation.
  • Page 3 Mount recording cylinder Attach cylinder holding Cut tape that secures Remove the holding clip Remove cap for cartridge that secures lower pen arm pen by turning it counter- to the main shaft. nut. upper pen arm. by sliding it upward. clockwise. Push pen lifting lever away Set time.
  • Page 4 ● Precautions ・ At exhaust port of airconditioner or at a place subject to direct sunlight. ・ In dusty of sooty environments. 1. Handling batteries (for battery-operated model (quartz type) only) ・ Use of blocking the ventholes of the acrylic cover. ・...
  • Page 5: Loading Batteries

    For battery-operated model (Quartz type) ●   Verifying operation Cylinder starts rotating soon after the batteries are installed. Confirm that LED Recording cylinder ●   (green) is blinking. Battery ●   Checking battery condition with LED compartment Knob LED (green) goes out when the voltage of the battery becomes 2.2VDC ±10% or less under normal ambient.
  • Page 6 For spring-wound model 2. Install 1-day chart for 1-day operation 1-day chart (400 sheets/box) may be purchased separately. ●   Change cylinder speed pinion 3. Install the recording cylinder Confirm that the pinion is engaged properly with the gear as shown in Pinion 168H Fig.
  • Page 7: Specifications

    ● External fan (option) SPECIFICATIONS The external fan (option) can be attached to the acrylic cover. The fan improves response by Cat No. 7210-00 / 7211-00 7215-00 directly pulling surrounding air into the instrument. NS Ⅱ-Q (Quartz type) NS Ⅱ-S (Spring-wound type) Model Drum 1 day, 7 day and 32 day changed...
  • Page 8 3-4, Kanda-kajicho, Chiyoda-ku, Tokyo 101-0045 Japan URL: http://www.sksato.co.jp/english/ V.02. 18...

This manual is also suitable for:

Sigma-ii ns ii-s7210-007211-007215-00