secondary latch switch.
3. Test the continuity of the switches with the door open and closed
with an ohm meter on the lowest scale.
Normal continuity readings should be as followed.
Primary Latch
Switch
Secondary
Latch switch
Power relay B
14.2. Short Switch and Monitor Circuit
1. Unplug the lead wires from the HV inverter primary terminals.
2. Connect the test probes of the ohm meter to these leads
3. Test the continuity of the short switch with the door open and the
door closed using the lowest ohm scale.
Monitor switch
14.3. Magnetron
Continuity checks can only indicate an open filament or a shorted magnetron. To diagnose an
open filament or shorted magnetron.
1. Isolate the magnetron from the circuit by disconnecting the HV
leads
2. A continuity check across the magnetron filament terminals
should indicate one ohm or less
3. A continuity check between each filament terminal and the
magnetron case should read open.
Door Open
Door Closed
infinite
0
(Open)
infinite
0
(Open)
infinite
infinite
(Open)
(Close)
Door Open
Door Closed
0
infinte
(Close)
(Close)