Honeywell HM512W1005 Homeowners Operating Manual page 9

Honeywell hm512w1005: user guide
Hide thumbs Also See for HM512W1005:
Table of Contents

Advertisement

Available languages

Available languages

Cleaning and maintenance
2. Turn the manual shut-
off valve at the bottom
of the tank to the
"Unlock" position.
5. Use tap water to flush loose minerals
from the tank. Sediment screen at
tank's bottom is removable. For a more
thorough cleaning, soak tank in warm,
soapy water, then rinse clean. Tank is
also dishwasher-safe.
Sediment screen
Once clean, reattach tank by securing the latch. Engage the water valve to the cam shaft, and
"Lock" the shut-off valve. The "Press Reset" light will blink at start-up. Push the RESET button
to ready the humidifier.
3. Grip the white water
valve arm and slide it
back within the bracket
to disengage from the
tank.
M24777
TrueSTEAM Direct-Injection Humidifier
M24779
6. Carefully rub minerals off of the heating
element and reservoir walls. Scouring
pads suitable for non-stick pots or pans
are suitable for cleaning the TrueSTEAM
reservoir walls and components within the
tank.
M24856

4. Firmly grip the tank
bottom. Push down the
cover's safety button and
pull the latch forward to
release the tank.
Note: Latch does not come
off humidifier with tank.
M24857
69-2035EFS—05
M24778

Hide quick links:

Advertisement

Table of Contents
loading