be cleared to 0.
3. To release from Usage Screen Mode, press any operation button
on VCR or insert a cassette tape in this mode. VCR will return to
normal operation mode.
5.1.3. GROUNDING FOR ELECTROSTATIC BREAKDOWN
Prevention
1. Human body grounding
Use the antistatic wrist strap to discharge the static electricity
from your body.
2. Work table grounding
Put a conductive material (sheet) or steel sheet on the area where
the optical pickup is placed and ground the sheet.
Caution:
The static electricity of your clothes will not be grounded through
the wrist strap. So take care not to let your clothes touch the optical
pickup.
5.1.4. METHOD FOR EJECTING THE DVD TRAY MANUALLY
1. Insert a Screwdriver or similar object into the Eject hole.
2. Press it gently, and then pull the Tray fully out.
Fig. 3
Fig. 4
14