TABLE OF CONTENTS SYMBOLS ...................................4 TECHNICAL DATA ..............................5 SAFETY INSTRUCTIONS & WARNINGS ........................6 GENERAL................................6 SHOCK PREVENTION ............................8 FIRE AND EXPLOSION ............................8 EQUIPMENT WARNING LABELS ..........................8 ASSEMBLY INSTRUCTIONS .............................9 Assembly Instructions for Ministand Lift ........................9 ADJUSTING THE WIDTH OF THE LEGS ......................13 LIFT ASSEMBLY EXPLODED VIEW ........................14 With shifter base ..............................14 With pedal base ..............................15...
SYMBOLS WARNING: this symbol is intended to alert the user CAUTION: this symbol is hazards unsafe intended to alert the user practices which could presence result in serious bodily important operating and harm. maintenance instructions which could prevent product damage NOTE: this symbol...
TECHNICAL DATA DIMENSIONS WEIGHT DATA Hoisting height at: Description Description Max. Total lift 45.5 Shipping Total lift height 1090 42.9 1580 62.2 Complete base 17.7 Hoisting height at connecting points 37.6 1540 60.6 Complete mast with controls & actuator 10.86 Connecting points to base end 12.2 24.6...
BHM medical patient lifts are designed specifically for use with slings and accessories manufactured by BHM Medical. We cannot ensure the safety of a transfer, and therefore cannot be held responsible, for any incident that may occur as a result of the use of slings or accessories produced by another manufacturer.
Page 7
SAFETY INSTRUCTIONS & WARNINGS DO NOT push the lift over uneven or rough ground, particularly if loaded DO NOT attempt to push or pull a loaded lift over a floor obstruction which the casters are unable to ride over easily. DO NOT BUMP the lift down steps, loaded or unloaded.
SAFETY INSTRUCTIONS & WARNINGS SHOCK PREVENTION AVOID violent shock during transportation. DO NOT touch or use a lift with bare conductors or a damaged power cord. Electrically live equipment can electrocute a patient. If the lift or charger has any exposed or damaged wires, contact your local dealer immediately.
ASSEMBLY INSTRUCTIONS Assembly Instructions for Ministand Lift There are three different models of Ministand lift : With legs activated by a shifter (A). With legs activated by a pedal (B). With electrical legs (activated by the control box) (C). The assembly instructions remain the same for all lifts unless specified otherwise. 1.
Page 10
2. Remove the securing bolts on the base mast post. Slide mast over the post and secure with the two bolts and lock washers. 3. For power base shifter only: Unpack the actuator from the mast prior to fixing it to the floor lift. Actuator wire must be oriented upward and its label...
Page 11
5. Install the top extremity of the actuator and fix it to the boom bracket with the clevis pin assembly. 6. Insert the knee support union into the mast bracket and adjust with the knob place below the bracket. Insert the knee pad on the knee support union and adjust for proper height with the knob placed behind the knee pad.
Page 12
8. Insert the shifter arm onto the shifter plate assembly (for models with shifter arm only). 9. Place batteries into the control box.
ADJUSTING THE WIDTH OF THE LEGS The base of the lift can be set with the legs opened or closed. Adjustments of the base varied according to the model: Shifter base: The adjustments are made by changing the position of the shifter: Disengage the shifter plate by pulling the shifter arm then push it to the left will close the legs.
CONTROL BOX DETAILS (with integrated charger) POWER CORD FOR CTRL BOX WITH INTERGRATED CHARGER (DEPENDING OF THE COUNTRY) Item Number Part Number Title...
BATTERY MAINTENANCE & SERVICE MAINTENANCE AND REPLACEMENT OF BATTERIES Battery Systems: The Ministand uses sealed lead-acid batteries mounted within the control box. Unlike nickel-cadmium batteries, lead-acid batteries are not subject to a memory effect. Therefore they should not be completely drained before recharging. The control box is equipped with an automatic control shut off after 20 seconds of inactivity to prevent any battery drainage while the lift is in the stand-by mode.
MAINTENANCE & SERVICE MAINTENANCE AND REPLACEMENT OF BATTERIES To remove the battery pack from the control box push the 2 latch buttons located on each side of the control box at the same time and pull straight out toward you. The battery pack shell is formed of 2 pieces.
Page 27
Check the following: Is the fuse OK? If not, replace it with an identical 10 amp fuse. Part # C8FGMA10. Are the wire and battery connectors free from corrosion? Is the cable damaged, if so, replace it with new part (see exploded view). Is there any damage or evidence of abuse to the battery pack casing? A complete battery pack assembly can be ordered (See exploded view).
MONTHLY INSPECTION DETAILS Refer to diagram on the following page for the location of each inspection area. These procedures are supplied as a guideline for personnel who are responsible for the maintenance and safety inspections of patient handling devices. The manufacturer accepts no responsibility for ongoing inspections and checks.
LOGBOOK Product Name : MINISTAND Product Serial Number : Date of purchase : Warranty Period : Distributed By : Owner Checklist : Ensure the lift is serviced regularly as the Monthly inspection details on page 23. Contact an authorised Distributor / Service Agent immediately if there are any problems with the operation of the device.
Page 31
Service Type: Pre-delivery Periodic inspection Minor Major Condition report : Action taken : Date : Inspected by: _________________ ____________________ ____________________ Printed Signature Service Type: Pre-delivery Periodic inspection Minor Major Condition report : Action taken : Date : Inspected by: _________________ ____________________ ____________________ Printed Signature...
Page 32
Service Type: Pre-delivery Periodic inspection Minor Major Condition report : Action taken : Date : Inspected by: _________________ ____________________ ____________________ Printed Signature Service Type Pre-delivery Periodic inspection Minor Major Condition report : Action taken : Date : Inspected by: _________________ ____________________ ____________________ Printed Signature...
Medical will solely determine evaluation of warranty claim. The warranty does not apply to problems arising from normal wear or failure to adhere to the instructions in this manual. BHM Medical Inc. slings are void of warranty if not laundered as per instructions on the Sling Label.
Need help?
Do you have a question about the MINISTAND 865 Series and is the answer not in the manual?
Questions and answers