Advertisement

Quick Links

MODELS
865XXXXX
866XXXXX
Avril 2005 (rev. 5)
TECHNICAL MANUAL
MINISTAND
STAND-UP LIFT
Phone:
Toll free: 1 800-868-0441
Fax:
E-mail:
5155 Spectrum Way, Unit 33
London, SW13 0PS, United Kingdom
Tel: +44 (0)7740 717146
Fax: +44 (0)870 1619681
2001, Tanguay Street
Magog (Quebec)
Canada J1X 5Y5
(819) 868-0441
(819) 868-2249
www.bhm-medical.com
Mississauga (Ontario)
Canada L4W 5A1
14 Cross St.
#001.20076

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MINISTAND 865 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for BHM Medical MINISTAND 865 Series

  • Page 1 MODELS 865XXXXX 866XXXXX TECHNICAL MANUAL MINISTAND STAND-UP LIFT 2001, Tanguay Street Magog (Quebec) Canada J1X 5Y5 Phone: (819) 868-0441 Toll free: 1 800-868-0441 Fax: (819) 868-2249 E-mail: www.bhm-medical.com 5155 Spectrum Way, Unit 33 Mississauga (Ontario) Canada L4W 5A1 14 Cross St. London, SW13 0PS, United Kingdom Tel: +44 (0)7740 717146 Fax: +44 (0)870 1619681...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS SYMBOLS ...................................4 TECHNICAL DATA ..............................5 SAFETY INSTRUCTIONS & WARNINGS ........................6 GENERAL................................6 SHOCK PREVENTION ............................8 FIRE AND EXPLOSION ............................8 EQUIPMENT WARNING LABELS ..........................8 ASSEMBLY INSTRUCTIONS .............................9 Assembly Instructions for Ministand Lift ........................9 ADJUSTING THE WIDTH OF THE LEGS ......................13 LIFT ASSEMBLY EXPLODED VIEW ........................14 With shifter base ..............................14 With pedal base ..............................15...
  • Page 4: Symbols

    SYMBOLS WARNING: this symbol is intended to alert the user CAUTION: this symbol is hazards unsafe intended to alert the user practices which could presence result in serious bodily important operating and harm. maintenance instructions which could prevent product damage NOTE: this symbol...
  • Page 5: Technical Data

    TECHNICAL DATA DIMENSIONS WEIGHT DATA Hoisting height at: Description Description Max. Total lift 45.5 Shipping Total lift height 1090 42.9 1580 62.2 Complete base 17.7 Hoisting height at connecting points 37.6 1540 60.6 Complete mast with controls & actuator 10.86 Connecting points to base end 12.2 24.6...
  • Page 6: Safety Instructions & Warnings

    BHM medical patient lifts are designed specifically for use with slings and accessories manufactured by BHM Medical. We cannot ensure the safety of a transfer, and therefore cannot be held responsible, for any incident that may occur as a result of the use of slings or accessories produced by another manufacturer.
  • Page 7 SAFETY INSTRUCTIONS & WARNINGS DO NOT push the lift over uneven or rough ground, particularly if loaded DO NOT attempt to push or pull a loaded lift over a floor obstruction which the casters are unable to ride over easily. DO NOT BUMP the lift down steps, loaded or unloaded.
  • Page 8: Shock Prevention

    SAFETY INSTRUCTIONS & WARNINGS SHOCK PREVENTION AVOID violent shock during transportation. DO NOT touch or use a lift with bare conductors or a damaged power cord. Electrically live equipment can electrocute a patient. If the lift or charger has any exposed or damaged wires, contact your local dealer immediately.
  • Page 9: Assembly Instructions

    ASSEMBLY INSTRUCTIONS Assembly Instructions for Ministand Lift There are three different models of Ministand lift : With legs activated by a shifter (A). With legs activated by a pedal (B). With electrical legs (activated by the control box) (C). The assembly instructions remain the same for all lifts unless specified otherwise. 1.
  • Page 10 2. Remove the securing bolts on the base mast post. Slide mast over the post and secure with the two bolts and lock washers. 3. For power base shifter only: Unpack the actuator from the mast prior to fixing it to the floor lift. Actuator wire must be oriented upward and its label...
  • Page 11 5. Install the top extremity of the actuator and fix it to the boom bracket with the clevis pin assembly. 6. Insert the knee support union into the mast bracket and adjust with the knob place below the bracket. Insert the knee pad on the knee support union and adjust for proper height with the knob placed behind the knee pad.
  • Page 12 8. Insert the shifter arm onto the shifter plate assembly (for models with shifter arm only). 9. Place batteries into the control box.
  • Page 13: Adjusting The Width Of The Legs

    ADJUSTING THE WIDTH OF THE LEGS The base of the lift can be set with the legs opened or closed. Adjustments of the base varied according to the model: Shifter base: The adjustments are made by changing the position of the shifter: Disengage the shifter plate by pulling the shifter arm then push it to the left will close the legs.
  • Page 14: Lift Assembly Exploded View

    LIFT ASSEMBLY EXPLODED VIEW With shifter base...
  • Page 15: With Pedal Base

    LIFT ASSEMBLY EXPLODED VIEW With pedal base...
  • Page 16: With Power Base

    LIFT ASSEMBLY EXPLODED VIEW With power base...
  • Page 17: Lift Parts List

    LIFT PARTS LIST...
  • Page 18: Shifter Base Exploded View

    SHIFTER BASE EXPLODED VIEW #700.20061.09 (SHIFTER BASE KIT ASSEMBLY)
  • Page 19: Pedal Base Exploded View

    PEDAL BASE EXPLODED VIEW #700.20060.09 (PEDAL BASE KIT ASSEMBLY)
  • Page 20: Power Base Exploded View

    POWER BASE EXPLODED VIEW #700.20062.09 (POWER BASE KIT ASSEMBLY)
  • Page 21: Control Box Details (With Integrated Charger)

    CONTROL BOX DETAILS (with integrated charger) POWER CORD FOR CTRL BOX WITH INTERGRATED CHARGER (DEPENDING OF THE COUNTRY) Item Number Part Number Title...
  • Page 22: Battery Pack Details

    BATTERY PACK DETAILS Item Catalog Number Description Number 200.16200 BATTERY PACK TOP 200.16210 BATTERY PACK BOTTOM 200.16220 BATT PACK RELEASE BUTTON 403.10500 BATTERY 12V 5Ah 200.16270 CONTACT BATTERY PACK 402.00033 WIRE JUMPER BATTERY PACK 000.02480 TAP SCREW PLASTITE 4.0 X 12 C8FGMA10 FUSE GMA 10 A...
  • Page 23: Charger Wiring Details

    CHARGER WIRING DETAILS...
  • Page 24: Battery & Control Box Wiring Details (With Integrated Charger)

    BATTERY & CONTROL BOX WIRING DETAILS (with integrated charger)
  • Page 25: Battery Maintenance & Service

    BATTERY MAINTENANCE & SERVICE MAINTENANCE AND REPLACEMENT OF BATTERIES Battery Systems: The Ministand uses sealed lead-acid batteries mounted within the control box. Unlike nickel-cadmium batteries, lead-acid batteries are not subject to a memory effect. Therefore they should not be completely drained before recharging. The control box is equipped with an automatic control shut off after 20 seconds of inactivity to prevent any battery drainage while the lift is in the stand-by mode.
  • Page 26: Maintenance & Service

    MAINTENANCE & SERVICE MAINTENANCE AND REPLACEMENT OF BATTERIES To remove the battery pack from the control box push the 2 latch buttons located on each side of the control box at the same time and pull straight out toward you. The battery pack shell is formed of 2 pieces.
  • Page 27 Check the following: Is the fuse OK? If not, replace it with an identical 10 amp fuse. Part # C8FGMA10. Are the wire and battery connectors free from corrosion? Is the cable damaged, if so, replace it with new part (see exploded view). Is there any damage or evidence of abuse to the battery pack casing? A complete battery pack assembly can be ordered (See exploded view).
  • Page 28: Monthly Inspection Details

    MONTHLY INSPECTION DETAILS Refer to diagram on the following page for the location of each inspection area. These procedures are supplied as a guideline for personnel who are responsible for the maintenance and safety inspections of patient handling devices. The manufacturer accepts no responsibility for ongoing inspections and checks.
  • Page 29: Diagram

    DIAGRAM...
  • Page 30: Logbook

    LOGBOOK Product Name : MINISTAND Product Serial Number : Date of purchase : Warranty Period : Distributed By : Owner Checklist : Ensure the lift is serviced regularly as the Monthly inspection details on page 23. Contact an authorised Distributor / Service Agent immediately if there are any problems with the operation of the device.
  • Page 31 Service Type: Pre-delivery Periodic inspection Minor Major Condition report : Action taken : Date : Inspected by: _________________ ____________________ ____________________ Printed Signature Service Type: Pre-delivery Periodic inspection Minor Major Condition report : Action taken : Date : Inspected by: _________________ ____________________ ____________________ Printed Signature...
  • Page 32 Service Type: Pre-delivery Periodic inspection Minor Major Condition report : Action taken : Date : Inspected by: _________________ ____________________ ____________________ Printed Signature Service Type Pre-delivery Periodic inspection Minor Major Condition report : Action taken : Date : Inspected by: _________________ ____________________ ____________________ Printed Signature...
  • Page 33: Warranty

    Medical will solely determine evaluation of warranty claim. The warranty does not apply to problems arising from normal wear or failure to adhere to the instructions in this manual. BHM Medical Inc. slings are void of warranty if not laundered as per instructions on the Sling Label.

This manual is also suitable for:

Ministand 866 series

Table of Contents