SPECIFICATIONS

Indoor unit model name
Mode
Power supply (phase, cycle, voltage)
Input
[kW]
Current*
[A]
Fan motor output* [kW]
[
K
Airflow rate (Low/Medium/High)
[CFM]
Noise level (Low/Medium/High) [dB]
Width
in (mm)
Depth
in (mm)
Height
in (mm)
Weight
lb (kg)
NOTE : Test conditions are based on ISO 5151.
Nominal cooling condition
Indoor :
81˚FDB/66˚FWB (27˚CDB/19˚CWB)
Outdoor :
95˚FDB (35˚CDB)
Pipe length :
24-9/16 ft (7.5m)
*Measured under rated operating frequency
Specifications and rating conditions of main electric parts
INDOOR UNIT
Model name
Item
(FUSE)
Fuse
(MV)
Vane motor
Terminal block
(TB)
OCHT669
Select "Test run" from the Service menu to bring up the Test run menu.
• Test run • Drain pump test run
Select "Input maintenance Info." from the Service menu to bring up the Maintenance information screen.
The following settings can be made from the Maintenance Information screen.
• Model name input • Serial No. input • Dealer information input
Make the settings for the indoor unit functions via the remote controller as necessary.
This setting is required only when the operation of CITY MULTI units is interlocked with LOSSNAY units.
Error history: Display the error history and execute "delete error history".
Refrigerant leak check (**): Refrigerant leaks can be judged.
Smooth maintenance (**): The indoor and outdoor maintenance data can be displayed.
Request code (**): Details of the operation data including each thermistor temperature and error history can be checked.
Error history of each unit can be checked via the remote controller.
When the remote controller does not work properly, use the remote controller checking function to trouble-
shoot the problem.
NTXCKS09A112AA NTXCKS12A112AA NTXCKS15A112AA NTXCKS18A112AA
Cooling
Heating
0.02
0.20
0.05
6.5/7.5/8.5
/min]
230/265/300
25/28/31
Nominal heating condition
68˚FDB/59˚FWB (20˚CDB/15˚CWB)
45˚FDB/43˚FWB (7˚CDB/6˚CWB)
24-9/16 ft (7.5 m)
NTXCKS09A112AA
NTXCKS12A112AA
MSBPC20M32 (Green label), MSBPC20M33 (Blue label): 12 V 300 "
TO OUTDOOR UNIT: 3P TO WIRED REMOTE CONTROLLER: 2P
Setting details
Cooling
Heating
Single phase 208/230 V, 60Hz
0.02
0.02
0.02
0.15
0.24
0.19
0.05
6.5/8.0/9.5
230/280/335
25/30/34
UNIT: 22-7/16 (570) PANEL: 24-19/32 (625)
UNIT: 22-7/16 (570) PANEL: 24-19/32 (625)
UNIT: 9-21/32 (245) PANEL: 13/32 (10)
UNIT: 30.6 (13.9) PANEL: 5.3 (2.4)
NTXCKS15A112AA
250V 6.3A
9
Cooling
Heating
Cooling
0.03
0.03
0.04
0.32
0.27
0.43
0.05
7.0/9.0/11.5
8.5/12.0/13.5
245/315/405
300/420/475
27/34/39
NTXCKS18A112AA
Heating
0.04
0.38
0.05
32/40/43