MAINTENANCE
Preventative Maintenance
The MART Corporation recommends that a preventative maintenance schedule be
established for processing the wastewater. More frequent processing shortens the
treatment time and the reduces the dosage rate of the Magic Dust. A good starting
point to determine frequency is to treat the solution after one week of use. If this
processing proves successful, try treating after two weeks and continue extending the
time between treatments to determine the best treatment frequency. Note that, if the
reservoir is allowed to become too saturated with contaminants, the treatment process
will become difficult or even impossible.
Service Schedule
The only servicing to the MART EQ-1
Processor is a thorough washdown after each
use. The Processor has a built-in rinse system
to facilitate the wash down procedure. It is
important to periodically remove the secured
cover on the upper Reactor Tank for inspection
and cleaning as necessary.
Empty and rinse the Processor after each use.
Never leave solution in the Processor for
extended periods. Aggressive chemicals can
damage the finish and corrode the tanks. Clean
the Sight Tube with the Sight Tube Brush
provided with the EQ-1 Processing System.
S
Sight tube & Brush
For Maintenance and Servicing of the EQ-1 Sump Pump and Mixer, refer
to the vendor-supplied operating manuals or speak with a MART Service
Technician at 1-800-567-6278.

Advertisement

loading
Need help?

Need help?

Do you have a question about the EQ-1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Mart EQ-1

  • Page 1 Sight Tube with the Sight Tube Brush provided with the EQ-1 Processing System. Sight tube & Brush For Maintenance and Servicing of the EQ-1 Sump Pump and Mixer, refer to the vendor-supplied operating manuals or speak with a MART Service Technician at 1-800-567-6278.
  • Page 2 EQ-1 TROUBLESHOOTING Problem Solution Mixer will not start. 1. Check electrical connections. Unplug unit from electrical receptacle and check power cord GFI unit. Press “RESET” button. Check Fuses for continuity. Check timer settings. Sump Pump will not Check electrical connections.