Using The Transition Detector Function - Hitachi CP-X253 User Manual

Hitachi cp-x253: user guide
Hide thumbs Also See for CP-X253:
Table of Contents

Advertisement

OPTION Menu
OPTION Menu (continued)
Item
SECURITY
(continued)
(continued on next page)
46

4. Using the Transition Detector Function

While the Transition Detector function is ON, when power switch is started to
supply to the projector, it might react as below.
• Transition Detector alarm shown below might appear on screen, if the
projector has been moved or re-installed.
• Transition Detector alarm might appear on screen, if the MIRROR setting
has been changed.
• Keystone adjustment feature has been prohibited as long as the Transition
Detector function is ON.
4.1 Turning On the
4.1-1 Use the ▲/▼ buttons on the SECURITY menu to
select Transition Detector and press the ► or the
ENTER button to display the Transition Detector
on/off menu.
Select TURN ON and the current angle and mirror
setting will be recorded.
• This feature may not function properly if the projector is
not in a stable position when TURN ON is selected.
4.1-2 If this function is set to TURN ON when the
vertical angle of the projector or mirror setting
at which the projector is turned on is different
than the previously recorded the Transition
Detector Alarm will be displayed and the
projector will not display the input signal.
Set the Transition Detector off in the SECURITY menu to display the input signal.
If the Transition Detector ALARM is displayed for about 5 minutes the lamp will turn off.
This function will activate only when the projector is started after the power
switch was turned off.
Transition Detector
4.2 Setting the
4.2-1 Use the ▲/▼ buttons on the SECURITY menu to select Transition
Detector and press the ► or the ENTER button to display the
Transition Detector on/off menu.
4.2-2 Use the ▲/▼ buttons on the Transition
Detector on/off menu to select TURN ON.
The ENTER PASSWORD BOX (small) will be
displayed.
4.2-3 Use the ▲/▼/◄/► buttons to enter a
PASSWORD. Move the cursor to the right side of
the ENTER PASSWORD BOX (small) and press
the ► button to display the CHECK PASSWORD
BOX, enter the same PASSWORD again.
4.2-4 Move the cursor to the right side of the
CHECK PASSWORD BOX and press the
► button to display the PASSWORD for
about 20 seconds, please make note of the
PASSWORD during this time.
Pressing the ENTER button will return to the
Transition Detector on/off menu.
• Please do not forget your Transition Detector PASSWORD.
Description
Transition Detector
Function
PASSWORD

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cp-rx70

Table of Contents