TROUBLESHOOTING

TROUBLESHOOTING

OSD Message

Table 9. OSD Message

Message
CHANGE THE LAMP
AFTER REPLACING LAMP,
RESET THE LAMP TIME.
CHANGE THE LAMP
AFTER REPLACING LAMP,
RESET THE LAMP TIME.
THE POWER WILL TURN OFF
AFTER
CHANGE THE LAMP
AFTER REPLACING LAMP,
RESET THE LAMP TIME.
THE POWER WILL
TURN OFF
AFTER 0 hr.
NO INPUT IS DETECTED
ON
SYNC IS OUT OF RANGE
ON
CHECK THE AIR FLOW
NOTE
ENGLISH-20
ENGLISH-20
The message shown at left appears after the lamp has
been used for more than 1300 hours.
The lamp is approaching the end of its life.
Power is switched OFF automatically when the lamp
reaches the end of its life. Prepare a new lamp for
1)
installation.
Always reset the lamp timer after replacing the lamp.
The lamp will reach the end of its life in
Power will be switched OFF automatically in
Replace the lamp as shown in P.17~18 "Lamp".
hr.
Always reset the lamp timer after replacing the lamp.
1)
The lamp has reached the end of its life. Power will be
switched OFF in a few minutes.
Switch power OFF immediately and replace the lamp as
shown in P.17~18 "Lamp".
Always reset the lamp timer after replacing the lamp.
No input signal found.
Check signal input connections and signal sources.
The horizontal or vertical frequency of the input signal is
not within the specified range.
Check the specifications of the equipment and the signal
source.
The internal temperature has risen.
Switch power OFF, and wait 20 minutes until the
equipment cools.
Check the following and Switch power ON again.
* Are the ventilation openings blocked.
* Is the air filter dirty.
* Is the ambient temperature in excess of 35°C.