Pakole LH-30 Operating Manual

Pakole LH-30 Operating Manual

Gas heat generator
Hide thumbs Also See for LH-30:

Advertisement

Quick Links

IMPORTANT: Before putting into operation the device , carefully read this
Failure by the consumer to comply with the rules of operation of the
heating device set forth in this manual may lead to undesirable
consequences. Keep this manual for answers to questions that arise
Neglect of the requirements set forth in this guide can lead to such
consequences as: material damage and serious harm
namely: fire, explosion, suffocation, carbon monoxide poisoning,
electric shock, which can lead to death.
Operation and installation of the device is allowed only after careful
reading of the operating
OPERATING MANUAL GAS HEAT
GENERATOR
OPERATING ON NATURAL AND
LIQUEFIED GAS
Industrial heating equipment
manual.
during operation .
GENERAL SAFETY REQUIREMENTS
and strict compliance with the
manual
specified in it.
to human
page 1 of 13
health,
requirements

Advertisement

Table of Contents
loading

Summary of Contents for Pakole LH-30

  • Page 1 OPERATING MANUAL GAS HEAT GENERATOR OPERATING ON NATURAL AND LIQUEFIED GAS Industrial heating equipment IMPORTANT: Before putting into operation the device , carefully read this manual. Failure by the consumer to comply with the rules of operation of the heating device set forth in this manual may lead to undesirable consequences.
  • Page 2: Table Of Contents

    CONTENT Possible malfunctions and methods their elimination9 .......... Safety ..........information2 Storage9 ............................maintenance10 ..........Unpacking......... the device3 Prevention10…………………………………… ................Service10………………………………………................Specifications11 ..........General .........characteristics Applications12…………………………………..............of the Appendix No112 ......................device3 Appendix No212 ........................Warranty13 ..........
  • Page 3 - When installing and operating , adhere to the current SAFETY INFORMATION requirements and rules in relation to gas-using equipment. - The connection of the device to the power supply WARNING should be carried out in strict accordance with the Operating Manual .
  • Page 4: Unpacking

    Unscrew the screw at the end of the locking rod, at the inlet or outlet of - Do not use air duct elements then remove the rod and the locking plate. the device that are not recommended by the manufacturer. GENERAL When replacing spare parts use only original spare...
  • Page 5: Principle

    DESIGN AND PRINCIPLE overheating WORK DEVICE sensor Gas supply system : For the safe operation of the device, the network gas pressure must be at least 30 mbar, but not exceed 60 mbar. After connecting the gas connection kit to the network and the device, open the gas tap, after which the gas will begin to be supplied through the gas filter, solenoid valve, nozzles into the...
  • Page 6 Т – temperature difference in Kelvin 110/100 – the value gives 10% premium for fast warm-up Pakole recommends using the gas connection kit they 103/100 – the value gives 3% surcharge on the heat loss of the supplied, which includes a flexible hose, a filter, a ball device body valve.
  • Page 7: Device

    80 kW 1950 Rice. 6 Overall dimensions of the device DEVICE PENDANT Overall dimensions For Warning Deformation in consequence of Heat Power Extensions length Suspension (e.g. chain) must be at [kW] least 400 mm. Attach suspension under Roof or Ceiling 30 kW 1130 on Reference beams or supports, between pillars or...
  • Page 8: Instrument Control7

    will last until the air temperature in the room drops below the temperature set on the thermostat and the thermostat starts the heating mode, in which the light INSTRUMENT CONTROL signal of the white button should light up. After reaching the set temperature in the room, the thermostat turns off The heat generator type LH is equipped with an the heating mode, stops the fan and the light signal of...
  • Page 9: Disabling

    The process of the device and, having detected any malfunction, give a signal to the electronics, which Disabling the device immediately stops the operation of the device. Disconnect the device in the following sequence: Make sure that all buttons on the control panel in a depressed state and that no lights are on.
  • Page 10 SERVICE AND - Check the gas inlet and outlet pressure on the solenoid valve measuring nozzles PREVENTIVE The device does not work after repeatedly trying to start MAINTENANCE the ignition cycle Possible causes: Preventive maintenance - Damaged solenoid valve NOTICE: Never perform preventive...
  • Page 11 , it must be cleaned! After-sales service NOTICE: Never perform maintenance on an energized or operating appliance. This can lead to burns or Fuel consumption electric shock. LH-30 LH-40 LH-50 LH-60 LH-70 Natural gas Preventive work Performed Specialized Service Service 3.00...
  • Page 12 If you need to change the type of gas , please contact the authorized service department. APPLICATION The heat consumption for incoming air "H" is Annex No. 1 calculated as follows: H = A.V.C . T x 10 Heated room: Where is A - number of air exchanges per (a) 15 m x 30 m x 4 m = 1800 m3...
  • Page 13 Motor Heat regulator Minimum Gas Pressure Controller 4 Outdoor Thermostat 5 Airflow sensor 6 Overheat sensor 7 Ionization flame control 8 Spark plug ignition Solenoid valve Capacitor...
  • Page 14 Warranty Gas heat generators of the LH type are guaranteed for 24 months from the date of sale, provided that the consumer complies with the rules of transportation, storage and operation set forth in the Passport and Operating Manual. During the warranty period, if the consumer discovers defects, the manufacturer replaces the failed components and parts of the heater free of charge: for this purpose, a defective unit must be sent to the manufacturer with an act drawn up by a representative of the gas management together with the owner of the heater.

This manual is also suitable for:

Lh-40Lh-50Lh-60Lh-70Lh-80

Table of Contents