Repair Parts List - Lennox ELITE EL296DFE Installation Instructions Manual

Gas furnace downflow air discharge
Table of Contents

Advertisement

Repair Parts List

The following repair parts are available through Lennox
dealers. When ordering parts, include the complete fur-
nace model number listed on the CSA nameplate -- Exam-
ple: EL296DF045XE36B. All service must be performed
by a licensed professional installer (or equivalent),
service agency, or gas supplier.
Cabinet Parts
Outer access panel
Blower access panel
Top Cap
Control Panel Parts
Transformer
Integrated control board
Door interlock switch
Blower Parts
Blower wheel
Motor
Motor mounting frame
Blower housing cutoff plate
B − Horizontal separation between
C − Exhaust pipe length
NOTE − Flue gas may be acidic and may adversely affect some building materials. If flue gases impinge
on the building materials, a corrosion−resistant shield should be used to protect the wall surface. The
shield should be constructed using wood, sheet metal or other suitable material. All seams, joints, cracks,
etc. in affected area, should be sealed using an appropriate sealant.
A − Clearance above grade or
average snow accumulation
intake and exhaust
D − Wall support distance from top
of each pipe (intake/exhaust)
Heating Parts
Flame Sensor
Heat exchanger assembly
Gas manifold
Combustion air inducer
Gas valve
Province of Ontario, Horizontal Sidewall Vent Appli-
cations Only
For exterior horizontal venting applications, the 2" X 1.5"
reducer for 2" venting at the point where the exhaust pipe
exits the structure is not required in direct or nondirect
vent applications in the Province of Ontario. In these ap-
plications, the vent should be oriented such that the ex-
haust plume is unobjectionable. If the installation requires
more separation between the flue gases and the building
structure, a reducer may be installed on the exhaust pipe
to increase the flue gas velocity.
Addendum For All Porvinces Of Canada
See below for venting in all provinces of Canada. Lennox
approves the following termination for use in all provices
of Canada.
C
D
B
12"
A
2" (51MM)
Vent Pipe
12" (305 mm) Min. 12" (305 mm) Min.
6" (152 mm) Min.
6" (152 mm) Min.
24" (610 mm) Max.
24" (610 mm) Max.
Per: Saskatchewan Code of Practice
6" (152 mm) Max.
Page 58
3" (76MM)
Vent Pipe
6" (152 mm) Max.