Filter blocked in water inlet hose
First, release water pressure in the supply hose:
1.
2.
3.
4.
5.
6.
36
Turn off the tap!
Select any programme (except Spin/Drain).
Ü
Select
(Start/Pause). Leave programme for approx. 40
seconds.
#
Press the
button. Appliance is switched off. Pull out the
mains plug!
Clean the filter:
Disconnect the hose from the water tap.
Clean filter with small brush.
and/or for standard and Aqua-Secure models:
Remove hose from the rear of the appliance.
Take out filter with pliers and clean.
Connect the hose and check for leaks.