Download Print this page

Le Veil iCigar Hybrid DCH-220 Instructions

Advertisement

Quick Links

Recalibrating the Hygrometer
Each Le Veil humidifier is equipped with a capacitive humidity
sensor, the same used in commercial laboratories. Most digital
hygrometers available are equipped with resistive sensors which can
have a RH variance of +-10%. Please make sure the
hygrometer used to match humidity has a capacitive humidity sensor.
To calibrate any Le Veil Humidifier, hold the 'MODE' button (keep
holding it) and before the numbers flash in the bottom right corner,
immediately adjust the meter with the 'UP' and 'Down' buttons. The
numbers on the upper left side of the humidifier will increase or de-
crease depending on what you need. Use this function to match the
humidifier to the other hygrometer that you are trying to match it to.
Tips
Humidors over 100ct should utilize full power by
connecting the Hybrid to a power source via the
included cables.
Be sure to adjust the air out ventilation depending
on your humidor size. Larger humidors need a more
open vent while smaller humidors will need the vent
to be smaller or fully closed.
The Le Veil Hybrid will check humidity every 3 mins
and run the fan if needed on battery save mode
'ON/S'.
Factory Pre-set
70%
Humidifier Accuracy
+/- 3%
Humidity Range
40% ~ 90%
Wall Outlet Power
100~ 240V AC,
12V DC
Engineered in USA
Manufactured in China
Patent rights issued
and /or pending
www.leveil.us
Humidifier Instructions
Le Veil iCigar Hybrid DCH-220/22
Thank you for purchasing the Le Veil Hybrid. Please read this manual in
its entirety to fully enjoy the benefits and features of this product.
Humidifier features
Easy to read display
Temperature
Relative Humidity
3 day average
Calibratable hygrometer
Rechargeable battery with micro USB port
Low battery and water alarm indicator
Maintains Up to 300CT humidors
Product Assembly Diagram
Note
The fan will not turn on if the sponge is dry.

Advertisement

loading

Summary of Contents for Le Veil iCigar Hybrid DCH-220

  • Page 1 Le Veil iCigar Hybrid DCH-220/22 Each Le Veil humidifier is equipped with a capacitive humidity Thank you for purchasing the Le Veil Hybrid. Please read this manual in sensor, the same used in commercial laboratories. Most digital its entirety to fully enjoy the benefits and features of this product.
  • Page 2 'DOWN' buttons to raise or lower the target humidity/RH setting. • The Le Veil Hybrid is equipped with a rechargeable Li-Ion battery and needs to be fully charged before using it for the first time. If the Hybrid The humidifier fan will turn on and off depend- has been inactive for a while it is recommended to fully charge it before ing on what the target humidity is set to.

This manual is also suitable for:

Icigar hybrid dch-22