Range Hood Instruction Manual FRHWM5002-30 IMPORTANT: READ AND SAVE THESE INSTRUCTIONS NOTICE: Installer: Leave this guide with the homeowner Homeowner: Keep this guide for future reference...
INDEX CUSTOMER CARE SERVICE INFORMATION SAFETY INFORMATION CARE AND CLEANING LED LIGHTS CONTROLS PRODUCT AND ACCESSORIES INSTALLATION MANUAL TROUBLESHOOTING...
Customer Service: 1-866-231-8893 opt. 2 ext.214 Or email: mysupport@forno.ca If your product ever requires servicing, be sure to use a FORNO Factory Certified Service provider recommended by our customer care center. All Factory Certified Service providers are carefully selected and thoroughly trained by us.
Page 4
THE WIRE CONNECTION MUST BE DONE BY SPECIALIZED TECHNICIAN The manufacturer will not be held liable for any damages resulting from incorrect or improper installation. The minimum safety distance between the cooker top and the extractor hood is 25” (some models can be installed at a lower height, please refer to the paragraphs on working dimensions and installation).
mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction. ACCESSIBLE PARTS MAY BECOME HOT WHEN USED WITH COOKING APPLIANCES. Clean and/or replace the Filters after the specified period (Fire hazard). See paragraph Care and Cleaning.
LED LIGHTS ALWAYS SWITCH OFF THE ELECTRICITY SUPPLY AT THE MAIN PANEL BEFORE CARRYING OUT ANY OPERATION ON THE APPLIANCE. To change the bulbs 1. Open the filter and find the spring of the light, push the spring and the lights will be slip out. CAUTION: BULB MAY BE HOT.
INSTALLATION MANUAL Warning! Before processing with installation, read the Recommendations and Suggestions in the User Manual. Prepare for installation A. If you have an outlet to the outside (vent outside), your cooker hood can be connected by means of an extraction duct (with an interior diameter of 6” or 150mm) B.
Page 9
Drill 3 holes to accommodate the bracket. Screw and tighten the bracket onto the wall with the screws & screw plugs provided. (Fig. 3 & 4)
Page 10
Screw Holes on wall Screw plug Wall bracket Drill 2 extra holes for fixing screws & screw plugs, to connect the hood onto the wall. (Fig.6) Lift the cooker hood and hang onto the wall bracket hook. (Fig.5) Fix the one-way-valve to the air outlet of the cooker hood. The exhaust pipe can be attached onto the one-way-valve as shown.
Page 11
Chimney installation *There are 2 chimney brackets, one is slightly shorter for the lower chimney. The longer bracket is for upper chimney. Drill 2 holes to tighten the shorter bracket on the wall by screws. Hang the lower chimney on the bracket.
Page 12
Take the upper and lower chimneys off from the brackets. (Fig.10) Attach the exhaust pipe onto the one-way-valve. (Fig.11) There are alternative ways to attach the upper chimney to the bracket. You may either hang the lower and upper chimneys onto the brackets (Fig.12), or lock the chimney to the bracket by 2 screws at two sides (Fig.13)
Page 13
Tightened the lower chimney to the hood with 2 screws. The chimney installation for vent outside is done. *For vent inside Charcoal filter (not included) can be used to trap odors. To install the charcoal filter, need to disassemble the grease filter by pressing the lock and pull it downward. (Fig.14) Plug the charcoal filter into the unit and turn it clockwise to lock.
TROUBLESHOOTING Failure Cause Solution The fan blade is jammed. Switch of the unit and repair by qualified Light on, but fan does not work service personnel only. The motor failure. light bulb burn. Replace the bulb with correct rating. Both light and fan Power cord Check the plug to make sure it is...
Need help?
Do you have a question about the FRHWM5002-30 and is the answer not in the manual?
Questions and answers