Warming Drawer WWD30-2
Cabinet Supports:
NOTE: When the warming drawer is installed with a built-in oven, additional clearance between openings may be
required. Check that oven supports do not obstruct the interior dimensions required for the warming drawer.
NOTE: Dimensions in parentheses are in millimeters unless otherwise specified.
The warming drawer may be supported by either a solid 7/8" (22) platform or 2" (51) x 2" (51) or 2" (51) x 4" (102)
runners. The platform or runners must be level, rigidly mounted and flush with the bottom edge of the opening.
They must be able to support 200 lbs. (90.7 kg).
NOTE: Make sure that the platform or runners are level. There is no way to level the warming drawer once it has
been installed.
Warming Drawer Installation:
Install a 2" (51) x 2" (51) or 2" (51) x 4" (102) anti-tip block
against the rear cabinet wall.
Turn power off to the electrical outlet.
Slide the left corner of the warming drawer into the open-
ing.
NOTE: A 6 foot power cord is supplied with the unit.
Depending on the outlet location, the unit can be set in
front of opening and plugged in.
If the electrical outlet is installed inside the opening, plug
the power cord into the outlet. The excess cord should be
coiled and secured directly behind warming drawer. If the
outlet is located in an adjacent cabinet, thread the power
cord through the hole in the cabinet wall. Push the drawer
back into the opening until the front flange is flush with
the cabinet front. Make sure the power cord does not get
trapped under the warming drawer.
Open the warming drawer to its full extension. Then, drill pilot holes in each corner of the warming drawer through
holes in the side frame and install the wood screws provided with the unit.
Installation Specifications:
The following pages provide the overall dimensions, finished rough
opening dimensions and electrical placement for the Wolf warming
drawer with stainless steel drawer front. For information on integrat-
ed Drawer Fronts, see the installation instructions provided with the
product.
Wolf recommends using a 33" (838) wide cabinet for the warming
drawer with stainless steel drawer front. A minimum 30" (762) wide
by 24" (610) deep cabinet is required with a minimum base support
of 200 lbs (91 kg).
(See Figure 2-3 and
7
29
/
"
8
(759)
OVERALL WIDTH
Figure 2-3. Overall Unit Dimensions
2-5)
26 1/4" (667)
OVERALL DEPTH
3
10
/
"
8
(264)
3
22
/
"
4
(578)
BEHIND FRAME

Installation Information

Figure 2-2. Drilled Pilot Holes for Securing Unit
(See Figure
M O D E L W W D 3 0
with Stainless Steel Drawer & Integrated Front
Overall Width
Overall Height
Overall Depth
Overall Depth (behind frame)
Minimum Cabinet Width
Minimum Cabinet Depth
Minimum Base Support
Opening Width
Opening Height
9"
Opening Depth
(229)
Dimensions may vary to + – 1 / 8 " (3).
Allow 3/8" (11) Additional depth for cord thickness
Figure 2-4. Overall Cabinet Dimensions
2-3
Anti-Tip Block
Pilot Holes
2-2)
29 7/8" (759)
10 3/8" (264)
26 1/4" (689)
22 3/4" (578)
30" (762)
24" (610)
200 lbs (91 kg)
28 5/8" (727)
9 1/8" (232)
23 7/8" (606)