• The motion detector covers an area 50 feet (15.24 m) out and
over and angle of 105˚. For best detection, locate the motion
sensor so that intruders move across
detection zone patterns, rather than
toward or away from the sensor.
• Check areas for potential sources
of false alarms. Remember that the
sensor responds to quick changes
in heat patterns within its coverage
pattern. Avoid placing in direct or
reflected sunlight, or near objects that
can be heated quickly by sunlight.
Do not place the product looking at
windows. Don't place it near heating
or cooling sources, like heater ducts
or air conditioners, which might direct
hot or cold air onto the sensor. Avoid
appliances such as space heaters
which can rapidly heat up.
• Check that premises are cleared and assets secured before
arming.
• Check that motion detectors are not obstructed. Do not allow
sources of heat in range of the motion sensors.
• Take into consideration the normal use of the area:
Are there bats, mice, or other animals that could activate the
sensor?
• Do not obstruct the coverage pattern with furniture or other
equipment.

Test the System

It is recommended to test the system periodically. This system test
will test each of the active sensors.
NOTE: The MOBILELOCK
TM
website and phone menu is subject
to change.
Go online to www.dewaltmobilelock.com or call the phone menu
system (1-410-329-9477) to perform a system test.
TO COMPLETE THE SYSTEM TEST THROUGH THE WEBSITE
1. Go online to www.dewaltmobilelock.com and enter login and
password.
2. Select Unit Customization.
3. Select unit.
4. Select System Test. The MOBILELOCK
all the ACTIVE sensors in the following order: vibration, door
contact, motion, and tamper. As you trip each sensor, the
MOBILELOCK
TM
unit will sound an alarm. A cellular notification
will not be sent. Continue tripping sensors until the test is
complete. The test will automatically time out after 5 minutes or
when each of the sensors has been tripped.
TO COMPLETE THE SYSTEM TEST THROUGH THE
PHONE MENU
1. Call 1-410-329-9477 and enter login and password.
2. Select Unit Maintenance from the main menu.
3. Select Status Update followed by System Test.
4. Status will offer the following information:
• Armed/disarmed/scheduled
• Battery level
• Cellular signal strength
• Sensor settings
• Alarm siren setting
5. Select Perform a System Test. The MOBILELOCK
cycle through all the ACTIVE sensors in the following order:
vibration, door contact, motion, and tamper. As you trip each
sensor, the MOBILELOCK
notification will not be sent. Continue tripping sensors until
the test is complete. The test will automatically time out after
5 minutes or when each of the sensors has been tripped.