6. Maintenance

Explosion-proof light fittings need regular maintenance according to the national rules of the country
they are installed. Especially components which are important for the Explosion Category have to be
carefully checked. Therefore it must to be checked very carefully:
diffuser, housing and gaskets for any kind of damages
the correct installation and tightness of explosion-proof cable glands and explosion-proof locking
screws (Torques see Chapter 3, Technical Data).
all parts of plastic inside the light fitting to attend to colour change, deformation and damaging.
the tight fit of the conductor and the condition of the cable insulation.
that the light fitting is closed correctly and the gasket is effective.
The maintenance of the fitting has to be done following the actual international and national
regulations.
6.1 Cleaning the light fitting
 Danger of ignition due to electrostatic charging at the plastic parts of the light fitting!
!
Only clean the inside of the glass and case of the light fitting (as well as its plastic parts)
with a damp cloth. For this only use cold or lukewarm water (if necessary with a mild
cleaning agent) together with a viscose sponge or a soft fibrous-free cloth!
Pay attention to the following in case of application of this light fitting in dusty atmospheres:
Dust deposits have got thermal insulation characteristic features. It is necessary to clean the fitting from
dust regularly. In case the dust layer may be higher than 5 mm it must be ensured that the surface
temperature of the light fitting does not exceed the maximum permissible surface temperature of the
specific dust considering the thickness of the dust layer. The dust layer must not exceed 50 mm at any
time.
6.2 Repair- and maintenance works
 The light fitting may only be opened if it has been disconnected from the mains supply
completely!
!
 It is allowed to open the light fitting in a non-explosive (non hazardous) atmosphere
only!
 For applications in dusty atmospheres the light fitting must be cleaned before opening!
 Ensure that no dust can get into the light fitting when it is open!
 Replace damaged explosion-proof parts by original spare parts from the Adolf Schuch
GmbH only!
6.3 How to replace the emergency battery
 Only original batteries as per the type plate on the battery must be used for replacing
the battery (see Chapter 3, Technical Data)!
!
Version without battery box:
Separate the emergency battery electrically and remove it from the light fitting (see Chapter 4.2
Section: Connecting an emergency battery).
Insert a new emergency battery and establish an electrical connection.