Gas Requirements - Samsung NX60 8 Series Installation Manual

Gas slide-in range
Hide thumbs Also See for NX60 8 Series:
Table of Contents

Advertisement

Available languages

Available languages

Installation requirements
CAUTION
Do NOT lift or handle the unit by the cooktop frame.
C2
C1
C4
C3
Fig. 1
16 English
Install_NX60T8755SS_AP_DG68-01326A-01_MES+EN.indb 16
Install_NX60T8755SS_AP_DG68-01326A-01_MES+EN.indb 16
1. The counter top around the cut-out
should be flat and leveled (See hatched
area on Fig. 1).
2. Before installing the unit, measure the
heights of the two cabinet sides (C1 ~ C4),
front and back (See Fig. 1) from the floor
to the top of the counter.
3. Level the range using the four leveling
legs so that the height from the floor
to the underside of the cooktop frame
is greater than the tallest cabinet
measurement by at least
/
".
1
16
4. Slide the unit into the cabinet (DO NOT
PUSH THE UNIT HARD). Make sure the
center of the unit aligns with the center
of the cabinet cut-out.
5. The metal flange under each side of the
cooktop MUST be placed over the cabinet
countertop for proper unit support. The
cooktop should NOT rest directly on the
countertop or else it could cause damage
to the cooktop voiding the warranty.
Level the unit if needed.

Gas requirements

Provide adequate gas supply
This range is designed to operate at a pressure of 10 in (25 cm) of water column
on LP gas (propane or butane).
Make sure you are supplying your range with the type of gas for which it is
designed. Do not attempt to convert the appliance from the gas specified in this
manual to a different gas without consulting the gas supplier.
For LP gas, the pressure supplied must be between 10 in and 13 in (25 cm and
33 cm) of water column.
When checking for proper operation of the regulator, the inlet pressure must be at
least 1 in (2.5 cm) greater than the operating (manifold) pressure as given.
The pressure regulator located at the inlet of the range manifold must remain in
the supply line.
A flexible-metal appliance connector used to connect the range to the gas supply
line should have an I.D. of 0.5 in (1.3 cm) and be 5 ft (152 cm) in length for ease of
installation. In Canada, flexible connectors must be single-wall metal connectors no
longer than 6 ft (183 cm) in length.
Do not kink or damage the flexible metal tubing when moving the range.
2021-02-19 오후 6:49:25
2021-02-19 오후 6:49:25

Advertisement

Chapters

Table of Contents
loading