Plasma Panel Replacement Method; Remove The; Remove The Fan; Remove The Rear Terminal Cover - Panasonic TH-58PY700M Service Manual

Table of Contents

Advertisement

TH-58PZ700A / TH-58PY700AZ / TH-58PY700M / TH-58PY700MR

6 Plasma panel replacement method

6.1.
Remove the Back cover
1. See Service Hint. (Section 5)
6.2.

Remove the fan

1. Disconnect the relay connectors.
2. Remove the screws (×3
fan B.
each) and remove the fan A and
6.3.
Remove the rear terminal
cover
1. Remove the screws (×12

2. Remove the rear terminal cover.

6.4.

Remove the P-Board

Caution:
To remove P.C.B. wait 1 minute after power was off for
discharge from electrolysis capacitors.
1. Unlock the cable clampers to free the cable.
2. Disconnect the connectors (P2, P5, P9, P10, P11, P12, P23
and P25).
3. Remove the screws (×8
4. Remove the screws (×28
10
, ×4
, ×2
).
) and remove the P-Board unit.
) on the back side.