6 Plasma panel replacement method
6.1.
Remove the Back cover
1. See Service Hint. (Section 5)
6.2.
Remove the fan
1. Disconnect the relay connectors.
2. Remove the screws (×3
fan B.
each) and remove the fan A and
6.3.
Remove the rear terminal
cover
1. Remove the screws (×12
2. Remove the rear terminal cover.
6.4.
Remove the P-Board
Caution:
To remove P.C.B. wait 1 minute after power was off for
discharge from electrolysis capacitors.
1. Unlock the cable clampers to free the cable.
2. Disconnect the connectors (P2, P5, P9, P10, P11, P12, P23
and P25).
3. Remove the screws (×8
4. Remove the screws (×28
10
, ×4
, ×2
).
) and remove the P-Board unit.