Table 12 Volume Of Water Per Cleaning; Table 13 Tightening Torques (81125) - ABB XAC17976 Original Operation Manual

Table of Contents

Advertisement

Operation Manual / 4 Product description / A100-L
6
Periodic maintenance
Repeating the cleaning
If the cleaning is still unsuccessful after three processes, it is recommended to have the turbo-
charger checked and cleaned by an ABB Turbocharging Service Station if the engine values
are unsatisfactory.
Volume of water per cleaning process
Product
A165-L
A170-L
A175-L
A180-L
A185-L
A190-L
Table 12: Volume of water per cleaning process
The filling time is 4 ... 15 seconds.
Checking the filter plug
Figure 18: Filter plug view
Disassembly and checking of the filter plug (81125) is required if, 20 seconds after the clean-
ing process, water is still visible in filler opening B.
Loosen and remove the filter plug (81125) with box spanner
Clean the drill holes of the plug
Fit filter plug (81125).
Part number
A165-L
81125
G1/2"
45 Nm
Table 13: Tightening torques (81125)
© Copyright 2016 ABB. All rights reserved.
A170-L
A175-L
G1/2"
G1/2"
45 Nm
45 Nm
HZTL4034_EN
Quantity [dm
3
2.0
2.0
3.0
3.0
3.0
3.0
A180-L
A185-L
G1/2"
G1/2"
45 Nm
45 Nm
Revision H
Page 45 / 113
]
A190-L
G1/2"
45 Nm
November 2016

Advertisement

Table of Contents
loading

This manual is also suitable for:

A170-l35

Table of Contents