ABB XAC17976 Original Operation Manual page 74

Table of Contents

Advertisement

Operation Manual / 4 Product description / A100-L
6
Periodic maintenance
6.4.2
Wet cleaning of compressor
Damage to hearing due to high noise level
Removing the screw plug (81126) from the filler orifice (B) may result in a
high level of noise. Carrying out wet cleaning on the compressor without ear
WARNING
protection may lead to serious hearing damage.
Always wear ear protection when carrying out wet cleaning on the com-
pressor.
Wear ear protection.
Figure 17: Overview of wet cleaning of compressor
81000
Filter silencer
81126
Lock
Remove insulation from flange of filter silencer (81000) (if present).
Unscrew lock (81126).
Measure volume of water according to the following table.
Pour this water into a clean can (A).
Carefully pour this water into the filling orifice (B) from the can.
Screw in lock and hand-tighten.
Fit insulation to flange of filter silencer (if present).
After cleaning, allow the engine to continue to run for at least 5 minutes under normal load.
© Copyright 2016 ABB. All rights reserved.
A
Can
B
Filler opening
HZTL4034_EN
Page 44 / 113
Revision H
November 2016

Advertisement

Table of Contents
loading

This manual is also suitable for:

A170-l35

Table of Contents