Macurco AimSafety PM150-CO2 User Instructions

Macurco AimSafety PM150-CO2 User Instructions

Carbon dioxide gas monitor

Advertisement

Quick Links

AimSafety™ PM150-CO
2
Carbon Dioxide Gas Monitor
User Instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AimSafety PM150-CO2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Macurco AimSafety PM150-CO2

  • Page 1 AimSafety™ PM150-CO Carbon Dioxide Gas Monitor User Instructions...
  • Page 2: Table Of Contents

    PM150-CO2 Portable Gas Monitor General Information ............................... 4 Specifications .................................. 4 PM150-CO2 Specifications ............................4 Sensor Specification ..............................4 Product Overview................................5 Monitor Overview ..............................5 Display Overview ..............................5 Activation ..................................6 Activating the PM150-CO ............................6 Error Messages ................................ 6 Bump Test ................................
  • Page 3 PM150-CO2 Portable Gas Monitor Appendix A – Table of Figures ........................... 21 Product Limited Warranty ..............................22 Technical Support Contact Information ..........................22 General Contact Information ............................22 WARNING Any unauthorized attempt to repair or modify the product, or any other cause of damage beyond the range of the intended use, including damage by fire, lightening, or other hazard, voids liability of the manufacturer.
  • Page 4: General Information

    PM150-CO2 Portable Gas Monitor 1 General Information The PM150-CO₂ is a portable single gas detector designed to detect the presence of carbon dioxide gas in ambient environment. When activated, PM150-CO₂ continuously monitors ambient air for the presence of carbon dioxide gas and alerts the user to potentially unsafe exposure with LED, vibrating, and audible alarms if gas concentration exceeds alarm set points.
  • Page 5: Product Overview

    PM150-CO2 Portable Gas Monitor 3 Product Overview 3.1 Monitor Overview LCD display Alarm LED Buzzer Power Button Function Key Gas sensor Figure 3-1 3.2 Display Overview Calibration / Setting Success Calibration / Setting Failure Measurement Unit Standard Gas Calibration Remaining Battery Alarm Condition Alarm Display Alarm Display...
  • Page 6: Activation

    PM150-CO2 Portable Gas Monitor 4 Activation 4.1 Activating the PM150-CO Move the monitor to a fresh air environment, which is free of hazardous gas. Press and hold down the power button for approximately two (2) seconds until the gas type (CO ) is displayed.
  • Page 7: Bump Test

    PM150-CO2 Portable Gas Monitor 4.3 Bump Test A bump test is used to test that the monitor is working properly. During a bump test, a known concentration of gas is applied to the sensor to verify that the sensor responds to the gas, and the alarms activate. This is the only way to effectively confirm that all characteristics of the monitor and the sensor are working correctly.
  • Page 8: Mode

    PM150-CO2 Portable Gas Monitor 5 Mode 5.1 Measuring Mode When activated, gas concentration is displayed in measuring mode 5.2 Display Mode In the measuring mode, by pressing Function key, the following icons will appear in the following order. Max value → STEL value → TWA value → 1 alarm set point →...
  • Page 9: Settings Mode

    PM150-CO2 Portable Gas Monitor 5.3 Settings Mode In the settings mode, users can adjust set points, perform calibration, and reset previous values. • To enter the setting mode, press and hold the Function key & power button simultaneously for three seconds.
  • Page 10: Setting Mode

    Data logs consisting of event log, bump, and calibrations are stored at one (1) minute intervals. To transfer event logs and data log to a computer: • Install the current AimSafety CO USB link software found at www.macurco.com/downloads Connect the detector to a computer via the supplied USB-C cable. • REV – 1.0 [34-2900-0211-5]...
  • Page 11: Menu Screens

    PM150-CO2 Portable Gas Monitor 7 Menu Screens 7.1 Menu Flow Chart Figure 7-1 REV – 1.0 [34-2900-0211-5] 11 | P a g e...
  • Page 12: Clear Max (Peak Values)

    PM150-CO2 Portable Gas Monitor 7.2 Clear Max (Peak Values) To delete the measured peak concentration in the detector, follow below steps. 1. Press the Function key & power button simultaneously and the Function key until CLr (max) is displayed. 2. Press the power button to clear the peak value. 3.
  • Page 13: Self-Test

    PM150-CO2 Portable Gas Monitor 7.6 Self-Test To perform the self-diagnostic test, follow below steps. 1. Press the Function key until Test is displayed 2. Press the power button for three seconds. In the “SELF” display, press the power button for three seconds to activate the self-test.
  • Page 14: Calibration

    PM150-CO2 Portable Gas Monitor 8 Calibration CAUTION Initial calibration is performed on all devices prior to shipment. The detector has the zero calibration (N2) and span calibration (CO2) The frequency of calibration depends on the use case. More frequent calibrations may be required depending on the frequency of use and personal risk.
  • Page 15: Span Calibration

    PM150-CO2 Portable Gas Monitor 8.3 Span Calibration 1. Assemble the calibration equipment with span gas cylinder. See Figure 8-1 2. In the “CAL” mode, press the Function key to move to the “SPAn” calibration. 3. Attach the calibration cap to the detector. 4.
  • Page 16: Software Manager

    PM150-CO2 Portable Gas Monitor 9 Software Manager 9.1 Software Overview Read Write Calibration Firmware Figure 9-1 • Sensor Type – The current sensor type in the device (CO₂, cannot be changed) • Serial Number – PM150-CO serial number • Firmware Version – Current firmware version of the unit (can change by upgrading) •...
  • Page 17: Read

    PM150-CO2 Portable Gas Monitor 9.1.1 Read The “Read” button (upper-left side first icon) allows a user to retrieve the stored data. 9.1.2 Write The “Write” button (upper-left side second icon) has one of the most important roles in this software interface. All configurations and customized settings will be saved by clicking “Write”...
  • Page 18: Window Menu

    PM150-CO2 Portable Gas Monitor 9.2 Window menu 9.2.1 Menu – File • Load(L) – Load the installed settings • Save(S) – Save the current settings • Exit(X) – Finish the work and exit the program 9.2.2 Menu – Tools • Calibration(C) –...
  • Page 19: Maintenance

    PM150-CO2 Portable Gas Monitor 10 Maintenance Front cover Sensor Battery Figure 10-1 Accessories Replacement Sensor 70-2900-0540-6 Replacement Sensor Filter (pk. 20) 70-2900-0554-0 Replacement Battery 70-2900-0532-0 Replacement Front Cover 70-2900-0533-7 Mini USB Charger 70-2900-0533-8 Rear cover Belt clip CAUTION Power off the device before disassembly. Replacement of components can impact product performance.
  • Page 20: Sensor Replacement

    PM150-CO2 Portable Gas Monitor Figure 10-2 10.1 Sensor Replacement Move to a fresh air environment and power off the detector. Remove the back case by unscrewing the six (6) screws. Remove the two (2) screws on the PCB. Carefully replace with the new sensor provided by the authorized dealers or AimSafety. Ensure the sensor pins match with the above image and the sensor is aligned with the PCB.
  • Page 21: Battery Charging

    PM150-CO2 Portable Gas Monitor 11 Battery Charging 11.1 To charge the battery: Connect the USB-C type cable with the charging port at the bottom of the device. Connect the USB port with a provided adaptor (5V, 1.2A) While charging, the backlight illuminates. After the charging is complete, the backlight turns off and a full battery symbol is displayed.