Protection class

6. Functional Characteristics

・ The output voltage of the LAN port is the input voltage of the
power input port of the network interchanger, and the maximum
output current per port is 700mA.
・ The UPLINK port can be connected to the upper-level interchanger
to achieve the network data communication function.
・ It provides three working modes, and you can choose whether to
supply power for the connected equipment and also choose
different output rates of the LAN port to meet the different needs
of users.
・ It provides a short circuit protection function. In case of a short
circuit in any LAN port, the network switch will cut off the power
supply to the port without impact on the power supply to other
ports. When the short circuit is released, it will automatically
recover the power supply.
・ It also supports the power supply through lines 1, 2, 3, 6 and lines
4, 5, 7, 8 and 8-core(4pairs) or 4-core(2pairs) cable is optional to
connect the terminal equipment. Where lines 1, 2, 4, 5 are the
positive terminals of the power, and lines 3,6,7,8 are the ground
lines, when the terminal load current is larger and the cable is more
than 50m,it is recommended to use the 8-core network cable.

7. Installation diagrams

7.1 Installation mode with rubber plug screws
IP30
・ Drill two screw holes spacing 10cmina proper place, insert the
rubber plug, and lock the screws.
・ Align the vacancy on the back of the equipment with the screw
head and hang the equipment on the screws.
・ The installation is completed.
7.2 Guiderail type installation mode
・ Pullout the slider on the back of the equipment and attach the
equipment to the rail rack of the machine box.
・ Buckle the slider back to the equipment to complete the
installation.
1

8. Description of system connection

8.1 Simple PoE Power Supply 10M Transmission Mode (PoE 10)
Power Supply
18~27V DC
9
10
2
UP Link, connect to
UP-Level Router
Connect to Other
Indoor/Outdoor Station